EN: Installation Sheet
Introduction
The EV1100-D series includes the EV1116-D and EV1116AM-
D PIR motion sensors. They have a patented mirror, pyro and
signal processing technology.
Installation guidelines
The technology used in these detectors resists false alarm
hazards. However, avoid potential causes of instability (see
Figure 1) such as:
•
Direct sunlight on the detector
•
Strong draughts onto the detector
•
Heat sources within the detector field of view
•
Animals within the detector field of view
•
Obscuring the detector field of view with large objects,
such as furniture
•
Objects within 50 cm of the anti-masking (AM) detector
•
Installing two detectors facing each other and less than
50 cm apart (only AM detectors)
P/N 146576999-1 (ML) • REV D • ISS 08MAR19
All manuals and user guides at all-guides.com
< 33 Ω
J4
J3
J4
J3
J4
J3
Ω
Normal
4.7 k
A
larm
9.4
kΩ
Tamper
Ω
Short
0
EV1116AM-D
J4
J3
CP
< 33 Ω
Normal
A
larm
EV1116AM-D
J4
J3
CP
Ω
Normal
4.7 k
A
larm
9.4
kΩ
Tamper
Ω
Short
0
AM/TF
Installing the detector
Figure 7
(1) Single core connection
(2) Standard connection (factory
default)
(3) Dual loop connection
CP Control panel
To install the detector:
1.
Lift off the custom insert and remove the screw
(see Figure 2, step 1).
2.
Using a screwdriver, carefully prise open the detector (see
Figure 2, steps 2 and 3).
3.
Fix the base to the wall between 1.8 and 3.0 m from the
floor. For flat mounting use a minimum of two screws (DIN
7998) in positions A. For corner-mounting use screws in
positions B or C (Figure 3). To install a pry-off tamper, use
position A or C.
4.
Wire the detector (see Figures 3 and 7).
J4
J3
J4
J3
J4
J3
CP
Ω
Normal
4.7 k
A
larm
9.4
kΩ
Tamper
Ω
Short
0
AM/TF
WT Walk test
AM Antimasking
D/N Day/night
Rtest
Remote test
3 / 10