Mounting (example of a JanBus topology)
4
Taking into consideration the installation instructions
for your basic device and your other modules (e.g.
ATTENTION
ATTENTION
check the respective bus connector installation!), install
Incorrect assembly of the data cable can destroy
Incorrect assembly of the data cable can destroy
the transfer module as follows when the system is de-
your basic device with modules or your system!
your basic device with modules or your system!
g
energized:
A defective or incorrectly assembled data cable
A defective or incorrectly assembled data cable
1. If not already done, insert the bus connector
between the transfer modules can lead to
between the transfer modules can lead to
destruction of your basic device and your modules
destruction of your basic device and your modules
output (JanBus interface) included in the scope
and thus to property damage.
and thus to property damage.
of delivery in the socket on the bottom of your
· Use a data cable with a 1:1 line connection for
· Use a data cable with a 1:1 line connection for
transfer module. Pay attention to the correct
the connection between the transfer modules!
the connection between the transfer modules!
bus connector (bus connector output and input)
· Always connect your transfer modules via
· Always connect your transfer modules via
during the assembly.
shield terminals with tension relief!
shield terminals with tension relief!
· Protect your system against overvoltages and
· Protect your system against overvoltages and
2. Press your transfer module with bus connector
electromagnetic disturbances by connecting
electromagnetic disturbances by connecting
onto the DIN rail (for type, see technical data)
the data cable shield to the shield terminal!
the data cable shield to the shield terminal!
until the bottom latches engages.
ATTENTION
ATTENTION
Basic device
Improper handling or rough handling can destroy
Improper handling or rough handling can destroy
your devices and modules!
your devices and modules!
Contacts, bottom bolts and retaining clips can
Contacts, bottom bolts and retaining clips can
be damaged or broken off during assembly/
be damaged or broken off during assembly/
disassembly.
disassembly.
· Never touch or manipulate the contacts!
· Never touch or manipulate the contacts!
End bracket
· Protect contacts during handling, transportation
· Protect contacts during handling, transportation
and storage!
and storage!
· Never use force to assemble/disassemble
· Never use force to assemble/disassemble
devices/modules!
devices/modules!
· If necessary, observe further usage information
· If necessary, observe further usage information
on the devices, modules and components of
on the devices, modules and components of
your measuring device and module topology.
your measuring device and module topology.
":
Example: Assembly of the transfer modules in a measurement device and module topology
7
Technical data
General information
Net weight
Approx. 55 g (0.12 lb) - 1 device
(with plug terminals)
approx. w = 18 mm (0.71 in),
Device dimensions
h = 90 mm (3.54 in),
d = 76 mm (2.99 in)
Width of the device in
1HP (1HP = 18 mm)
horizontal pitches (HP)
Installation position
discretionary
Mounting/assembly -
· TS 35/7.5 according to EN 60715
suitable DIN rails -
· TS 35/10
35 mm (1.38 in)
· TS 35/15 x 1.5
Protection class
IP20
Operating temperature
-10 °C (14 °F) .. +55 °C (131 °F)
Impact resistance
IK07 according to IEC 62262
Transport and storage
The following information applies to devices which are
transported and stored in the original packaging
Free fall
1 m (39.37 in)
Temperature
K55
-25 °C (-13 °F) up to +70 °C (158 °F)
5 to 95% at 25 °C (77 °F)
Relative humidity
without condensation
Ambient conditions during operation, see basic device
Interface
JanBus (proprietary)
· Via bus connector to series of devices
and modules.
· Via shield terminals between the
transfer modules with twisted pair,
shielded data cable (line connection
1:1), e.g.:
Lapp Unitronic LiYcY (TP) 4x2x0.5
· The maximum bus length of the
JanBus is 100 m.
3. Slide the contacts of the bus connector output
(transfer module) into the sockets of the basic
ATTENTION
ATTENTION
device bus connector or into the sockets of the
Modules are not recognized by the basic device
Modules are not recognized by the basic device
connected module so that the bus connectors
during the startup process!
during the startup process!
(devices) are coupled.
If there is no communication to the modules, the
If there is no communication to the modules, the
module functions are not supported (e.g. current
module functions are not supported (e.g. current
measurements).
measurements).
Spatially separated series of modules:
· Disconnect your system from the power supply
· Disconnect your system from the power supply
4. Insert the bus connector input in the sockets on
and check the condition of the bus connector
and check the condition of the bus connector
the bottom of the transfer module for the spatially
and the connections of your modules to the
and the connections of your modules to the
separated series of modules.
basic device (JanBus interface). If necessary,
basic device (JanBus interface). If necessary,
slide the contacts of the module bus connector
slide the contacts of the module bus connector
into the sockets of the basic device bus
into the sockets of the basic device bus
Transfer module
connector or the connected modules so that
connector or the connected modules so that
the bus connectors (devices) are linked.
the bus connectors (devices) are linked.
800-CON
· For spatially separated series of modules,
· For spatially separated series of modules,
check the connection of the transfer modules
check the connection of the transfer modules
with the connection via the shield terminals.
with the connection via the shield terminals.
Module 800-CT8-A
· If necessary, restart the basic device.
· If necessary, restart the basic device.
· If the specified measures are unsuccessful,
· If the specified measures are unsuccessful,
please contact our support team -
please contact our support team -
www.janitza.com
www.janitza.com
3.
Bottom latch
1.
2.
Module 800-CON
Bus connector output
Terminal connection capacity
Connectable conductors.
Only one conductor can be connected per terminal.
Single core, multi-core,
0.2 - 1.5 mm
2
, AWG 24-16
fine-stranded
Cable end sleeve
0.2 - 1.5 mm
, AWG 26-16
2
(not insulated)
Cable end sleeve
0.2 - 1 mm
2
, AWG 26-18
(insulated)
Tightening torque
0.2 - 0.25 Nm (1.77 - 2.21 lbf in)
Stripping length
7 mm (0.2756 in)
INFORMATION
Detailed information and technical data on the mod-
ule can be found in the user manual at
www.janitza.com (download area).
Technical data on the basic device and information
on how to proceed in the event of a fault can be
found in the usage information of your basic device.
6
6
Dismounting
Dismounting
Dismounting the transfer module 800-CON:
Dismounting the transfer module 800-CON:
1. Disconnect the system from the power supply! Secure
1. Disconnect the system from the power supply! Secure
it against being switched back on! Verify disconnection
it against being switched back on! Verify disconnection
from power! Ground and short circuit! Cover or block off
from power! Ground and short circuit! Cover or block off
neighboring parts that are under voltage!
neighboring parts that are under voltage!
2. Disconnect the wiring and the terminal.
2. Disconnect the wiring and the terminal.
3. Remove or shift the shield terminal and end brackets of
3. Remove or shift the shield terminal and end brackets of
your series of devices and modules.
your series of devices and modules.
4. Decouple the bus connector (JanBus interface) of
4. Decouple the bus connector (JanBus interface) of
the transfer module from the basic device and/or the
the transfer module from the basic device and/or the
connected module by pulling it out.
connected module by pulling it out.
5. Unlatch the bottom latches of the transfer module.
5. Unlatch the bottom latches of the transfer module.
Recommendation: Use a screwdriver for this
Recommendation: Use a screwdriver for this
(carefully!).
(carefully!).
6. Remove the DIN rail from the transfer module without
6. Remove the DIN rail from the transfer module without
touching or damaging the bus connector contacts.
touching or damaging the bus connector contacts.
ATTENTION
Handling your module too roughly may cause
Handling your module too roughly may cause
damage to the module and result in property
damage to the module and result in property
damage!
damage!
The bus connector contacts and the bottom latches
The bus connector contacts and the bottom latches
can be damaged or broken off during dismantling of
can be damaged or broken off during dismantling of
your module.
your module.
· Never wrench the module from the DIN rail
· Never wrench the module from the DIN rail
DIN rail
using force.
using force.
· Decouple the bus connector (JanBus interface)
· Decouple the bus connector (JanBus interface)
beforehand and carefully unlatch the bottom
beforehand and carefully unlatch the bottom
latch of the module using a screwdriver!
latch of the module using a screwdriver!
8 / 8
Screwdriver for
Screwdriver for
unlatching
unlatching
Bus connector
contacts
JanBus
interface
Bus connector
sockets
Bottom latch
Fig.
Fig.
Dismounting the
Dismounting the
transfer module
transfer module
ATTENTION
ATTENTION
Property damage due to dismantling or decoupling
Property damage due to dismantling or decoupling
the module during operation!
the module during operation!
Dismantling or decoupling the module while it is
Dismantling or decoupling the module while it is
communicating with the basic device can lead to
communicating with the basic device can lead to
damage to your devices!
damage to your devices!
· Disconnect your system from the power supply
· Disconnect your system from the power supply
before dismantling or decoupling the module!
before dismantling or decoupling the module!
Secure it against being turned back on! Verify
Secure it against being turned back on! Verify
disconnection from power! Ground and short
disconnection from power! Ground and short
circuit! Cover or block off neighboring parts that
circuit! Cover or block off neighboring parts that
are under voltage!
are under voltage!
7
Bottom latch
Bottom latch
Bus connector
contacts
DIN rail
DIN rail
JanBus
interface
Bus connector
sockets
Bottom latch
Terminal
Terminal
ATTENTION