12 V
1. Connect the red clamp to the positive (+) terminal.
2. Connect the black clamp to the negative (-) terminal.
3. Wiggle the clamps back and forth to ensure proper connection.
4. The LCD should activate. If the LCD does not activate see section:
[} 4]
7.3 Disconnecting the leads
When finished using the product:
1. Press the
button to switch the power OFF.
2. Disconnect the red clamp.
3. Disconnect the black clamp.
8 Operation
1
2
1. Connect the product to the vehicle battery terminals. See section:
2. Press the
button to switch the power ON.
à
If everything is functioning correctly the capacitor will start charging. See section:
status display
[} 3].
à
If there is a problem with the battery an error message will appear. See section:
Troubleshooting
[} 4].
3. Wait for a "beep" sound and READY to appear on the display.
à
Jump start the vehicle engine.
4. If ignition is successful, let the engine run to allow the battery to recharge, and disconnect
the product from the battery. See section:
à
If ignition is not successful, switch the product OFF, and repeat steps 2 - 3.
Notes:
In some cases when the ambient temperature is <0 °C, the LCD display may not activate
but the product will still function .
In such cases wait approximately 5 minutes for the audible "beep". This indicates the ca-
pacitor has reached full charge and is ready to jump start the vehicle engine.
9 Troubleshooting
Code
Possible cause
F01
Rechargeable battery voltage is
too high.
F02
Rechargeable battery voltage is
too low.
F03
Product has circuit malfunction.
F04
Rechargeable battery capacity is
<2 Ah.
LCD does
Cables not connected correctly.
not activate
Rechargeable battery voltage is
<5.5 V.
Weather is too cold (<0 °C).
10 Cleaning and care
Important:
– Do not use aggressive cleaning agents, rubbing alcohol or other chemical solutions.
They damage the housing and can cause the product to malfunction.
– Do not immerse the product in water.
1. Disconnect the product from the power supply.
4
Troubleshooting
3
READY
Connection
[} 3].
Disconnecting the leads
[} 4].
Suggested solution
Test the rechargeable battery, it should
be <13.8 V.
Test the rechargeable battery, it should
be >6 V.
Do not use the product.
Try to recharge the battery or consult a
qualified technician.
Recheck the connections.
Try to recharge the battery or consult a
qualified technician.
The LCD does not activate but the ca-
pacitor may still function. See section:
Operation
[} 4].
2. Clean the product with a dry, fibre-free cloth.
11 Disposal
This symbol must appear on any electrical and electronic equipment placed on
the EU market. This symbol indicates that this device should not be disposed of
as unsorted municipal waste at the end of its service life.
Owners of WEEE (Waste from Electrical and Electronic Equipment) shall dispose
of it separately from unsorted municipal waste. Spent batteries and accumulators,
which are not enclosed by the WEEE, as well as lamps that can be removed from
the WEEE in a non-destructive manner, must be removed by end users from the
WEEE in a non-destructive manner before it is handed over to a collection point.
Distributors of electrical and electronic equipment are legally obliged to provide free take-
back of waste. Conrad provides the following return options free of charge (more details on
our website):
in our Conrad offices
at the Conrad collection points
at the collection points of public waste management authorities or the collection points
set up by manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be disposed of.
It should be noted that different obligations about the return or recycling of WEEE may apply
in countries outside of Germany.
12 Technical data
Input ............................................... 12 V 10 A
Output............................................. 12 V
Starting current............................... 500 A
Peak current ................................... 1000 A
Capacitor ........................................ Charging: approx. 3 mins. (70 Ah battery)
Reverse polarity protection............. yes
Short circuit protection.................... yes
Operating conditions....................... -40 to +65 °C, 30 to 60 % RH (non-condensing)
LCD
Storage conditions.......................... -40 to +65 °C, 30 to 80 % RH (non-condensing)
Dimensions (W x H x D) ................. 136 x 57 x 200 mm
Weight (approx.)............................. 1.00 kg
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or the capture in
electronic data processing systems) requires prior written approval from the editor. Reprinting, also in part, is prohibited.
This publication reflects the technical status at the time of printing.
Copyright by Conrad Electronic SE.
*2799626_V1_0623_dh_mh_en 9007200127995531-2 I2/O1 en
Lifespan: approx. 10,000 cycles