Other particularities
WARNING
You must limit access for the S7-1500 F-Software Controller through access protection to persons who are authorized to
install or uninstall the software of the S7-1500 F-Software Controller.
The following warning applies to an S7-1500 F Software Controller on an IPC 627E, IPC 647E, IPC 677E or IPC 847E:
WARNING
When you download the safety program, you must perform a POWER OFF/POWER ON afterwards before you run a program
identification for acceptance.
Note
For an S7-1500 F Software Controller on an IPC 627E, IPC 647E, IPC 677E or IPC 847E, you must use at least the BIOS version
V25.02.10.
Note
With an S7-1500 F-Software Controller with a PC station up to and including V2.1, the "Delete Configuration" function is only
offered on the PC-station panel when no access protection (no protection) is set up on the F-CPU.
With a PC station as of V2.2, it is checked whether the Windows user is a member of the "Failsafe Operators" Windows user
group. If the logged-on Windows user is a member of the group, they can execute the "Delete Configuration" function even
when the F-password is set. If the logged-on Windows user is not a member of the group, the PC station behaves as up to
V2.1.
Note
If the S7-1500 F-Software Controller features an access protection, this is not deleted with "Delete Configuration" and is
retained.
Note
Required BIOS version for CPU 1505SP F prior to V2.5
For use of the CPU 1505SP F, you require BIOS version V2.00_02.01 or higher.
Note
The CPU clock must not be changed in RUN because this would result in a STOP. You can prevent this by disabling the energy-
saving function.
Note
Assignment of PROFIsafe addresses for F-modules via PROFIBUS on IPCs with S7-1500 F Software Controller prior to
V2.5
If you want to assign PROFIsafe addresses to F-modules that are being operated via PROFIBUS on an IPC with an
S7-1500 F-Software Controller, assign the PROFIsafe addresses to the F-modules and then perform a POWER OFF/POWER ON
of the PROFIBUS station.
Note
Loading the safety program or activating safety mode for S7-1500 F Software Controller prior to V2.5
After loading the safety program or activating safety mode, close the panel and then open it again to update the display on
the panel.
Note
Load safety program into an S7-1500 F-Software Controller (V21.8.3 or higher)
When you download the safety program to an IPC647E, IPC847E, IPC627E or IPC677E, the S7-1500 F Software Controller
needs to restart in very rare cases.
Repeat the download after the restart to complete the loading successfully.
Note
If you execute an update for a S7-1500 F Software Controller with V2.0 to a version > 2.0, the value "Last fail-safe change" is
set to the time of installation if a safety program is already installed on the S7-1500 F-Software Controller.
Note
The "Configuration file export" functionality requires the STEP 7 Safety add-on package as of V15 and an S7-1500 F Software
Controller prior to V2.5 with Windows.