The following is displayed for each F-I/O under "Fail-safe parameters":
•
F-parameter signature (with addresses)
•
Safety mode
•
F-monitoring time
•
F-source address
•
F-destination address
The following additional menu command is displayed in the "Settings" menu under "Protection":
•
Enable/disable F-password
Write access to F-blocks is not permitted.
Note
Controlling fail-safe inputs/outputs can result set the F-CPU to STOP.
Note
With the display firmware V2.5, the display is not refreshed and cannot be operated for a few minutes after loading program
changes. Afterwards, the display restarts.
Note
In the case of a redundant S7-1500HF system, the display of the "Last fail-safe change" in the display and web server is only
synchronized in the RUN-Redundant mode.
Web server
S7-1200/1500 F-CPUs show you the following on the start page of the Web server:
•
Safety mode activated/deactivated
•
Collective F-signature
•
Last fail-safe change
•
Version of STEP 7 Safety with which the safety program was compiled.
•
Information on the F-runtime groups
–
Name of F-runtime group
–
Residual runtime in deactivated safety mode
–
F-runtime groups signature
–
Current cycle time
–
Max. cycle time
–
Current runtime
–
Max. runtime
The following is displayed for each F-I/O on the "Module Information" web page in the "Fail-safe" tab:
•
F-parameter signature (with addresses)
•
Safety mode
•
F-monitoring time
•
F-source address
•
F-destination address
Write access to F-blocks is not permitted.
Note
Controlling fail-safe inputs/outputs can result set the F-CPU to STOP.
F-CPUs
A5E35635424-AM, 11/2022
21