6  Defrosting icon
7  "Fan ON" icon
8  "Water container full" icon
9  "Dehumidification mode" icon
Continuous display = dehumidfication is running
Flashing display =
Fault code
If the fault codes E3 – E4 – E5 are indicated in the "RH display"
 see "Possible faults".
Powering up
An acoustic signal will sound if you connect the power
cable to an electrical socket.
A fault has occurred when this acoustic signal does not
sound. Check the power supply cable, the electrical socket
and the fuse.
Press the
button to switch on the power to the air
dehumidifier.
The display 2  "RH of air" indicates the factory-set humidity of
air of 60 %. After 5 seconds the display indicates the actual
humidity of air.
The "RH" display indicates the humidity of air in a range
between 30 % and 90 %.
Shutting down
Press the
button again to switch off the power to the air
dehumidifier.
Setting the humidity value
Press the
button (Increase the RH setting) or
the RH setting) to set your desired relative humidity of air.
If the set RH value is lower than 30 %, the device will
continuously dehumidify and the indicator 2 displays "CO".
Hint: Normally, a relative humidity of air between 50 % and
60 % is sufficient to have a convenient indoor climate
and
to
prevent
components and furnishing.
If your desired RH value is lower than the actual RH by
3 %, the air dehumidifier will automatically start
(compressor).
The
continuously displayed.
If your desired RH value exceeds the actual RH by 3 %,
the air dehumidifier will automatically shut down
(compressor). The
(compressor and fan on)
dehumidification
is
running (compressor off - fan
on)
condensation
on
structural
icon
(dehumidification)
icon (dehumidification) is flashing.
At a room temperature under 20 °C not only condensation
water is generated on the cold evaporator surface, but also ice.
This ice blocks the heat exchanger so that the air flow is
impeded. The built-in automatic defroster removes the ice from
the evaporator. This allows a dehumidification operation down
not
to a temperature of +5 °C.
During defrosting, the
compressor continues to run, the fan is automatically stopped.
Once the defrosting process is finished the air dehumidifier
returns to the dehumidification mode and the
The air dehumidifier is equipped with an
operating hour counter.
The number of hours during which the device was in operation
in the past is displayed after the dehumidifier is turned on. The
amount of time during which the device remains on will be
added to the already elapsed time.
The water collecting container of the air dehumidifier is
equipped with a float switch which turns off the device when the
collecting container is full.
After 45 seconds, compressor and fan will automatically
stop, and an acoustic signal will sound. The
the fault code E4 will be displayed.
Another acoustic signal will sound every 5 minutes if the
water collecting container is not immediately emptied.
Removing the water collecting container
 LT 500:
1. Turn off the device.
(Reduce
2. Open the enclosure door.
3.
immediately.
4. Re-insert the container. Make sure that the container is
correctly positioned.
5. Close the hinged enclosure cover.
6. Restart the air dehumidifier. The
E4 should no longer be displayed.
Icon and fault code are further displayed? Remove the
container again and re-insert it properly.
is
 LT 800:
1. Turn off the device.
2.
then
3.
immediately.
Automatic defroster
icon is displayed on the display, the
Operating hour counter
W
a
t
e
r
o
u
W
a
t
e
r
o
u
Remove the container (8) and empty is
Press on the hinged cover (1)
.
Remove the container (pos. 2) and empty is
icon turns off.
t
l
e
t
t
l
e
t
icon and
icon and the fault code
and open it