Assembly transport wheels
1.
Secure the wheel axle (5) using the two
hexagon head screws M6x30 and install the cotter pins.
Secure the cotter pins against dropping out by
bending their ends using nippers
2.
Slide the washers (Ø 15.5) on the wheel
axle.
3.
Slide the wheels (6) and the washers on the
wheel axle. Secure the wheels using the securing pins (7).
After assembly, allow the device to stand vertically for
at least one hour before powering it up. In this way, the
refrigerant in it can settle.
L
o
c
a
t
i
o
n
o
f
t
L
o
c
a
t
i
o
n
o
f
t
Location
If possible, the air dehumidifier should be placed in the middle
of the room in order to have a good air circulation in the whole
room.
If this is not possible, locate the air dehumidifier so that air can
be sucked and discharged unhindered.
Keep a minimum distance of 10 cm to walls.
Place the air dehumidifier
 horizontally to ensure that the condensed water can flow off
unhindered
 away from a heat source (e.g. a radiator).
Make sure that windows and doors of the room to be
dehumidified are closed.
The dehumidifier must not be installed near burning
sources, such as an open flame, a switched-on gas
burner or electric heating with glowing spirals.
The device must be set up, operated and stored in a
room with a floor space greater than "A
("A
": see "Technical data  min. room area").
min
Electric supply
Compare the voltage listed on the device's type plate, e.g. 230
V / 50 Hz, with the mains voltage and connect the air
dehumidifier to a suited and and properly earthed electrical
socket.
Use an electrical socket with a rated voltage of 230 V with a
fault-current circuit breaker (30 mA).
Power system fuse protection
10 A
16
h
e
a
i
r
d
e
h
u
m
i
d
i
f
i
e
r
h
e
a
i
r
d
e
h
u
m
i
d
i
f
i
e
r
".
min
S
S
Before starting up
Did you transport the air dehumidifier in horizontal position or at
an angle large than 45°?
Allow the device to stand in vertical position for at least
one hour.
Notes
1. The air dehumidifier will not work if the set humidity value is
higher than that of the environment.
2. Only use the air dehumidifier at a room temperature
between 5 °C and 35 °C. The air dehumidifier will not
function out of this range.
3. Do not operate the air dehumidifier in heavily dust-laden or
chloric atmospheres.
4. Once the compressor has been started the fan motor and
the compressor must run for at least 3 minutes during
dehumidification. To prevent damages to the compressor,
you should wait for 3 minutes after a shut-down of the air
dehumidifier before you restart the device.
5. If the room temperature is under 10 °C and the relative
humidity of the ambient air is rather low an operation of the
air dehumidifier will not be necessary.
6. The device's air dehumidification performance depends on
room design, room temperature and relative humidity of the
room air.
7. Drain the container when it is full. Then, reinsert the empty
water container so that the device can work again.
8. Tranport this device only in upright (vertical) position.
9. If the device does not work or if the operation is suddenly
interrupted for unknown reasons,  see "Possible faults".
10. When the air dehumidifier is in operation the compressor
generates waste heat and the room temperature slightly
increases. This is considered a normal process.
Control panel
1  ON/OFF button
2  Relative humidity (in %) or fault display
3  "Increase RH" button
4  Operating hour counter
5  "Reduce RH" button
t
a
r
t
-
u
p
t
a
r
t
-
u
p

Werbung