TROUBLESHOOTING

Warning! Before opening up the calibration system, switch it off, unplug it from the mains and put up a warning sign to stop anybody
inadvertently switching it back on again.

CALIBRATION SYSTEM

Fault
calibration system is without function
magnetic switch „Resistor" does not
close; no current conduction
magnetic switches „load resistors" do not
open/close
Excess temperature indicator illuminated
Incorrect voltage displayed during
calibration
Voltage / current displayed at calibration
system differs from value metered using
external measuring instrument
no voltage present at rear plugs

FK 4000 / FK 4000 R COOLING UNIT

Error
Insufficient or no water through-flow
Insufficient cooling power
High-pitched running noises
Cause
fuse for calibration system primary circuit de-
fective
insufficient or no flow of water
excess temperature lamp illuminated
fuse for magnetic switch defective
fuse for calibration system internal circuit
defective
fuse for magnetic switch defective
fuse for calibration system internal circuit
defective
coolant temperature too high
voltage measurement switch set to "Upeak"
interferences on the signal measured
With a.c. voltage / current the calibration system
will display the mean value whereas external
meters usually show the actual value
fuse for mains plugs defective
Cause
Coolant level is too low
Constriction or foreign body in cooling circuit
Coolant pump fuse is defective
Coolant pump is defective
Coolant pump is stuck
Fan is defective
Coolant pump is defective
Coolant level is too low
Coolant pump is defective
11
Remedy
replace the fuse for the cal. syst. primary
circuit
check water flow; make sure there is an un-
hindered backflow
allow calibration system to cool down
replace fuse for magnetic switch
replace fuse for calibration system internal
circuit
replace fuse for magnetic switch
replace fuse for calibration system internal
circuit
allow calibration system to cool down
set voltage measurement siwtch to "Ueff"
use filter for external measuring instrument
use external measuring instrument that meters
mean value
replace fuse for mains plugs
Remedy
Top up with more coolant
Remove the constriction or foreign body
Replace the coolant pump fuse
Replace the coolant pump
Remove the coolant pump fuse and - using a
suitable slot-screw screwdriver inserted
through the motor-shaft lead-in - rotate the
motor shaft. After this, replace the coolant-
pump fuse.
Replace the fan
Replace the coolant pump
Top up with more coolant
Replace the coolant pump