8
LCD DISPLAY
9
PRESSURE RELIEF VALVE
a The purpose of this valve is to reduce the
pressure of the airbag 3 minutes after inflation.
This reduces the stress on the seams and fabric of
the airbag and ensures a longer life after inflation.
The relief valve is an electric solenoid valve that
is active 3 minutes after the end of inflation for a
maximum of 10 minutes or less, depending on the
residual energy in the batteries or supercapacitors.
After that, it closes automatically.
58
1
SUPERCAPACITOR CHARGE LEVEL
2
AA BATTERY POWER LEVEL: IF THE BATTERIES
ARE MISSING OR COMPLETELY EMPTY, THE ICON
BLINKS TO INDICATE THAT BATTERIES NEED TO BE
CHANGED OR INSTALLED.
3
DISPLAYS WHEN THE PRESSURE RELIEF VALVE IS
TRIGGERED
4
DISPLAYS IF THE SELF-TEST IS NOT FUNCTIONING
5
DISPLAYS WHEN THE USB-C CABLE IS CONNECTED
AND POWERED
a The relief valve also allows passive and partial
deflation of the airbag by reducing the pressure but
not allowing complete deflation of the airbag.The
function of the relief valve is checked 3x during
each self-test and can be clearly heard by the
characteristic ticking (like a Swiss watch!).

Werbung