W
The water collecting container of the air dehumidifier is
equipped with a float switch which turns off the device when the
collecting container is full.
After 45 seconds, compressor and fan will automatically
stop, and an acoustic signal will sound. The
the fault code E4 will be displayed.
Another acoustic signal will sound every 5 minutes if the
water collecting container is not immediately emptied.

Removing the water collecting container

1. Turn off the device.
2. Open the enclosure door.
3. Remove the container (8) and empty is immediately.
4. Re-insert the container. Make sure that the container is
correctly positioned.
Make sure that the container is correctly positioned and
the hose (a) is reinserted in the container's opening.
5. Close the hinged enclosure cover.
6. Restart the air dehumidifier. The
E4 should no longer be displayed.
Icon and fault code are further displayed? Remove the
container again and re-insert it properly.

Continuous or extended operation

In the case of a high humidity of air it is recommended to
operate the air dehumidifier in continuous mode. In
continuous mode it is not needed to empty the water
collecting container.
Proceed as follows:
1. Open the housing door and remove the stopper (9) from the
housing door.
18
a
t
e
r
o
u
t
l
e
t
a
t
e
r
o
u
t
l
e
t
icon and
icon and the fault code
2. Guide the hose (a) through the housing door.
3.
Use an adapter (b) to extend the hose (a) by a suitable
water hose (ID: approx. 13 mm) to allow water to flow out.
Pay attention to the following:
Make sure that the water can flow out unhindered.
Pipe the water preferably to a drain which is
positioned at a lower level.
Make sure that the hose remains in its position, is
routed with a descending gradient, is not kinked or
wound up.
T
r
T
Power off the device and disconnect the mains
plug before each transport.
Always transport the air dehumidifier in upright (vertical) position
to prevent compressor damages.
Hint: If you have transported the air dehumidifier in
another than upright position (horizontal or tilted),
allow the air dehumidifier to stand in upright position
for at least one hour before starting it up.