Herunterladen Inhalt Inhalt Diese Seite drucken

Automatic Defroster; Operating Hour Counter; Water Outlet; Removing The Water Collecting Container - ATIKA ALE 300 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3

Automatic defroster

At a room temperature under 20 °C not only condensation
water is generated on the cold evaporator surface, but also ice.
This ice blocks the heat exchanger so that the air flow is
impeded. The built-in automatic defroster removes the ice from
the evaporator. This allows a dehumidification operation down
to a temperature of +5 °C.
During defrosting, the
compressor continues to run, the fan is automatically stopped.
Once the defrosting process is finished the air dehumidifier
returns to the dehumidification mode and the

Operating hour counter

The air dehumidifier is equipped with an
operating hour counter.
The number of hours during which the
device was in operation in the past is displayed after the
dehumidifier is turned on. The amount of time during which the
device remains on will be added to the already elapsed time.
W
W
The water collecting container of the air dehumidifier is
equipped with a float switch which turns off the device when the
collecting container is full.
After 45 seconds, compressor and fan will automatically
stop, and an acoustic signal will sound. The
the fault code E4 will be displayed.
Another acoustic signal will sound every 5 minutes if the
water collecting container is not immediately emptied.

Removing the water collecting container

1. Turn off the device.
2. Open the enclosure door.
3. Remove the container (2) and empty is immediately.
4. Re-insert the container. Make sure that the container is
correctly positioned.
Make sure that the container is correctly positioned.
5. Close the hinged enclosure cover.
16
icon is displayed on the display, the
icon turns off.
a
t
e
r
o
u
t
l
e
t
a
t
e
r
o
u
t
l
e
t
6. Restart the air dehumidifier. The
E4 should no longer be displayed.
Icon and fault code are further displayed? Remove the
container again and re-insert it properly.
In the case of a high humidity of air it is recommended to
operate the air dehumidifier in continuous mode. In
continuous mode it is not needed to empty the water
collecting container.
Proceed as follows:
1. Open the housing door and remove the stopper (3) from the
housing door.
2. First push the hose (8) on the water drain nozzle (a) and
guide it then through the housing door.
icon and
Pay attention to the following:
Make sure that the water can flow out unhindered.
Pipe the water preferably to a drain which is
positioned at a lower level.
Make sure that the hose remains in its position, is
routed with a descending gradient, is not kinked or
wound up.

Continuous or extended operation

icon and the fault code

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis