IN CASE OF FAILURE
Failure type:
front cover not thoroughly closed
vacuum cleaner housing overheating
low suction power

TECHNICAL DATA

Technical parameters are indicated on the product nameplate.
Length of power cord: 4,2 m
Working radius: 5 m
NOTE! MPM agd S.A. reserves its right to modify the technical data.
Proper disposal of the product (waste electrical and electronic equipment)
Marking on the product indicates that after the service-life of the product expires, it should not be dis-
posed with other type of municipal waste. Used equipment may have a negative impact on the environ-
ment and health of people due to potentially containing hazardous substances, mixtures and components.
Mixing electric waste with other types of waste or disassembling those in an unprofessional manner may
cause a release of substances that are hazardous to the environment and health. Used equipment should
be handed-over to a point for collection of electric waste. In order to obtain detailed information regarding the
electric waste collection points, the user should contact the municipal point of electric waste collection or used
equipment processing department.
Possible causes:
dust bag not attached or attached
improperly
a slight housing temperature increase is normal, but if the temperature increases
considerably, immediately turn off the vacuum cleaner and contact the service
strongly contaminated filters
full dust bag
blocked hose or extension pipe
Instructions:
attach the dust bag properly
clean or replace the filters
replace the dust bag or empty the textile
bag
remove all items blocking the hose or pipe