6. FAULTS AND SOLUTIONS
The following cases are not always a fault. See the possible solutions before asking for service.
Problem
The infrared panel
does not turn on.
The surface of the
infrared panel
expands forward.
The surface of the
infrared panel only
warms up a little.
The infrared panel
makes a sound after
turning on.
56 FUAVE Reykjavik 700/900
Cause
- The appliance is not powered.
- The thermal protection has turned off the
appliance because it has fallen over, or
another object hits the front of the appliance
causing the surface temperature to rise to
130°C or more.
ATTENTION! This is normal and not a fault or
defect.
The material of the infrared panel expands
through the heat. During cooling, the
appliance returns to its original form.
- The power supply does not meet the
requirements.
- The ambient temperature is low.
ATTENTION! This is normal and not a fault or
defect.
- The material of the infrared panel and the
insulation expands through the heat.
ATTENTION! This is normal and not a fault
or defect. Always wait at least three minutes
after maintenance and/or repair before
turning on the appliance.
Solution
1.
Check that the plug is in the socket and that the
cable or plug is not damaged.
2.
Check that the RCD is switched on.
3.
Check that there is no power failure.
4.
Wait ten minutes and turn the appliance back
on.
ATTENTION! Do not start the appliance yet, unplug
it and contact Customer Service. See Foreword for
the contact details.
- Unplug the plug and allow the appliance to cool
down.
The appliance can be switched on again if it has
cooled down sufficiently.
- Check that the power supply meets the
requirements (see 'Technical Data').