Remote control

Model
Battery voltage required
Power consumption
Battery type and number
Temperature display accuracy
Temperature measurement accuracy
Frequency band
Maximum broadcast radio frequency power in the frequency
band(s) in which the radio equipment operates
Temperature range during use

2.4. Safety functions

The safety functions in the table are part of the remote control of the appliance.
1
ATTENTION!
The safety functions are only active when the appliance is set to manual control via the remote control (see Manual
remote control operation).
Protections
Protection in the case of a sudden drop in temperature
(only when the appliance is set to remote control operation)
Frost protection
(only when the appliance is set to remote control operation)
Automatic shutoff
(only when the appliance is set to remote control operation)
Tilt sensor
Thermal protection
USER MANUAL
RMT-10 / T1
2V tot 3V DC
0.2 mA
AAA x2
0.5°C
0.1°C
433 MHz
Maximum 15 dBm
−5°C tot +80°C
Remote control
When room temperature drops suddenly 3°C or more, the
appliance is automatically turned off.
After 15 minutes, the appliance is switched on and heats up
again. If the room temperature does not rise, the appliance
is automatically switched off again.
This cycle is repeated five times. The appliance is then
automatically switched off.
When room temperature drops to 5°C or below, the
appliance is automatically turned on by the remote control.
Even if the appliance is already turned off with the remote
control!
The appliance continues to heat the room until a room
temperature of 10°C is reached and then switches off
automatically.
When the appliance is set to remote control operation
and does not receive a signal from the remote control
for a period of five hours, the appliance will switch off
automatically.
When the appliance tilts, for example when knocked over,
the tilt sensor automatically switches off the appliance when
it tilts between 45° and 60° or more.
When the appliance is turned upright, the tilt sensor turns
the appliance on automatically.
See Turning the tilt sensor on and off for more information.
When the appliance falls over or another object hits the
front of the infrared panel and the surface reaches a
temperature of 130°C, the thermal protection disables the
appliance.