Filling the oil mister unit
CAUTION!
Before filling or removing the oil reservoir q
make sure that the compressed air mainte-
nance unit has been disconnected from the
compressed air source.
Remove the oil reservoir q by turning the
locking ring 0 clockwise (see fig. E). Fill the oil
reservoir q with suitable compressor oil until
the max. marking is reached (see Fig. B).
Then manually rotate the oil reservoir anticlock-
wise to the desired position q (do not use tools).
(fig. E)
Use
CAUTION!
Ensure that the connected compressed air line
is clean and oil-free so that the compressed
air maintenance unit can be used properly.
Also make sure that the compressed air
system is pressure-free. In order to minimise
pressure losses, it is preferable to keep the
compressed air lines as short as possible.
Connect the compressed air maintenance unit
to the compressed air source.
First release the locking device by pulling the
air pressure regulator 3 upwards (see Fig. F).
PDWE 8 B2
Set the air pressure regulator 3 to the lowest
setting by rotating it anticlockwise. The desired
settings are adopted by pressing the air
pressure regulator 3 downwards.
Connect the compressed air supply line of the
tool to be connected to the quick coupling 8
(on the right side – output) of the compressed
air maintenance unit. A triangle "▸" on the
surface of the unit indicates the flow direction
of the compressed air.
Connect the compressed air supply line of
the compressed air source via the connector
nipple 2 (on the left side inlet) of the compressed
air maintenance unit. A triangle "▸" is marked
on the surface in close proximity to the inlet,
which indicates the flow direction of the
compressed air.
(fig. F)
Before using the compressed air maintenance
unit, check the direction of the compressed air
flow using the "▸" mark on the surface. Incorrect
installation will not generate sufficient pressure.
GB │ IE