Herunterladen Diese Seite drucken

Parkside PDWE 8 B2 Originalbetriebsanleitung Seite 10

Vorschau ausblenden Andere Handbücher für PDWE 8 B2:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 14
Oil mister unit
The oil mister unit 9 is connected to the filter
unit 1. Its function is to lubricate the filtered
compressed air which is being transported in the
direction of the compressed air tool.
The fill level of the oil reservoir q (integrated in the
oil mister unit) can be inspected through the trans-
parent viewing window. Use only oil that is suitable
for this compressed air maintenance unit (see
above).
Turn the oil outlet screw 7 (mounted on the
sight glass) clockwise ("–") to reduce the
amount of oil required. Turn it anticlockwise
("+") to increase the amount of oil.
The integrated sight glass makes continuous
monitoring of the filtered compressed air
possible.
To top up the oil, unscrew the screw of the oil
refill inlet 6 with a suitable Allen key. Fill the
container with the help of a suitable funnel and
then replace the screw using the Allen key.
Fault
Causes
Oil outlet
screw 7 turned
too far in
direction ("–").
Insufficient
The compressed
lubrication.
air oil quantity is
too low, i.e.
below the
minimum fill
quantity.
The oper-
ating pres-
The pressure
regulator 3 is
sure of the
compressed
closed too
air is too
tightly.
weak.
PDWE 8 B2
Maintenance and cleaning
NOTE
The solution
Increase the
oil quantity
Pour more oil
into the oil
reservoir q.
Pay attention to
the maximum
filling quantity.
Increase the
pressure.
WARNING! RISK OF INJURY!
Disconnect the appliance from
the compressed air supply.
The compressed air maintenance unit must be
serviced and overhauled at regular intervals
to ensure proper functioning and compliance
with safety requirements. Improper and incor-
rect operation can lead to failures and
damage to the appliance.
Never use harsh and/or abrasive cleaning
agents or solvents. These could damage the
plastic parts of the compressed air mainte-
nance unit.
Never allow water to get inside the oiler.
Make sure that the housing and the inside of
the compressed air maintenance unit remain
free of dust and dirt. To ensure this is the case,
wipe the compressed air maintenance unit
regularly with a clean cloth.
Clean the compressed air maintenance unit and
the connections at regular intervals with a damp
cloth.
Empty the tank of the compressed air mainte-
nance unit at regular intervals. To do this, press
the drain valve w (see fig. G) on the underside
upwards. Please note that the compressed air
maintenance unit must be pressure-free for
safety reasons.
Disconnect the compressed air maintenance
unit from the compressed air source.
The drain valve w opens as soon as it is discon-
nected from the compressed air.
GB │ IE
 7

Werbung

loading