STIEBEL ELTRON WPM Bedienungsanleitung Seite 21

Wärmepumpen-manager
Vorschau ausblenden Andere Handbücher für WPM:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

OPeRATION
Menu
f Set the ECO temperature under SETTINGS / DHW / DHW TEM-
PERATURES / ECO TEMPERATURE.
f Set the times under PROGRAMS / DHW PROGRAM.
4.4.5 DHW MODE
Purpose: When the heating period is over and only DHW is re-
quired (summer mode).
DHW heating takes place according to the specified seven-day pro-
gram times. The heat pump switches between comfort tempera-
ture and ECO temperature. Within the selected seven-day program
times, the heat pump heats to comfort temperature.
f Set the comfort temperature under SETTINGS / DHW / DHW
TEMPERATURES / COMFORT TEMPERATURE.
f Set the ECO temperature under SETTINGS / DHW / DHW TEM-
PERATURES / ECO TEMPERATURE.
f Set the times under PROGRAMS / DHW PROGRAM.
Frost protection is activated for heating mode.
4.4.6 EMERGENCY OPERATION
Note
If emergency mode is enabled, higher operating costs
will result because of the second heat source.
Purpose: If the heat pump can no longer function. In many cases
the heat pump switches into this operating mode automatically.
Heat pumps with second internal heat source
For heat pumps with a second internal heat source, the emer-
gency/booster heater is activated for central heating and DHW
heating.
Heat pumps with second external heat source
If the heat pump is connected to an external second heat source
and your qualified contractor has enabled the corresponding pa-
rameters (THREADED IMMERSION HEATER or BOILER), the oper-
ating mode can be selected. The external heat source then takes
over operation of the DHW or central heating function, irrespective
of the dual mode changeover point.
www.stiebel-eltron.com
5.
Menu
Note
Not all appliance parameters and values are displayed in
the different menus; it depends which heat pump type
and accessories are connected.
Note
Some menu items are protected by a code and can only
be accessed and adjusted by a qualified contractor.
Note
The menu items shown in grey are visible only if the WPE
heat pump extension is connected.
5.1
Menu structure
INFO
SYSTEM
HEAT PUMP
ENERGY FOOTPRINT
DIAGNOSIS
SYSTEM STATUS
HEAT PUMP STATUS
HEAT PUMP ANALYSIS
SYSTEM
INTERNAL CALCULATION
NOTIFICATIONLIST
RELAY TEST SYSTEM
RELAY TEST HEAT PUMP
PROGRAMS
HEATING PROGRAM
DHW PROGRAM
COOLING PROGRAM
PARTY PROGRAM
HOLIDAY PROGRAM
HEAT-UP PROGRAM
PASTEURISATION PROGRAM
DHW CIRCULATION PROGRAM
… SWIMMING POOL PROGRAM
SILENT PROGRAM 1
SILENT PROGRAM 2
SETTINGS
VIEW
GENERAL
FAVOURITES
HEATING
DHW
HYBRID MODULE
COOLING
… SWIMMING POOL
… DIFFERENTIAL CONTROLLER 1
… DIFFERENTIAL CONTROLLER 2
… THERMOSTAT FUNCTION 1
… THERMOSTAT FUNCTION 2
COMMISSIONING
SOURCE
CHARGING PUMP CONTROL
HEATING
WPM |
21