OPeRATION
Operation
4.4
Selecting operating modes
On the start screen, the current operating mode is displayed
(e.g. ECO MODE).
WEDNESDAY 12. APR 17
OUTSIDE TEMPERATURE
ACTUAL WW TEMPERATURE
ACTUAL RETURN TEMPERATURE
ECO MODE
f If you want to select another operating mode, use the Touch-
Wheel. This takes you through the list of possible operating
modes. The current choice (list entry) is shown in the shaded
selection field.
Note
Since navigation to a new operating mode is always made
from the currently enabled mode, you may need to turn
in an anti-clockwise direction. All operating modes, apart
from DHW mode, apply to both heating and DHW.
f Confirm with OK.
Note
If the selection field shows POWER-OFF behind the op-
erating mode, then the heat pump will not heat or cool
during the blocking time.
The compressor and the internal electric reheating stag-
es are switched off. If a buffer cylinder is installed, the
heating circuit pumps will continue running.
You can ask your qualified contractor to configure an ex-
ternal heat source for the blocking time.
4.4.1 STANDBY MODE
Purpose: If the heat pump will not be running for a longer period.
The frost protection function is enabled.
4.4.2 PROGRAMMED OPERATION
Note
Installed remote controls are effective only in this oper-
ating mode.
Purpose: If you need heating and DHW.
Heating mode
Heating operation takes place according to the seven-day program
times specified for the heating circuits. The heat pump switches
between comfort temperature and ECO temperature. Within the
selected seven-day program times, the heat pump heats to com-
fort temperature.
f Set the comfort temperature for the relevant heating circuit
under SETTINGS / HEATING / HEATING CIRCUIT/COMFORT
TEMPERATURE.
20
| WPM
f Set the ECO temperature for the relevant heating cir-
f Set the times under PROGRAMS / HEATING PROGRAM for the
10:23 TIME
DHW heating
27.0 °C
DHW heating takes place according to the specified seven-day pro-
35.0 °C
gram times. The heat pump switches between comfort tempera-
28.0 °C
ture and ECO temperature. Within the selected seven-day program
times, the heat pump heats to comfort temperature.
f Set the comfort temperature under SETTINGS / DHW / DHW
f Set the ECO temperature under SETTINGS / DHW / DHW TEM-
f Set the times under PROGRAMS / DHW PROGRAM.
4.4.3 COMFORT MODE
Purpose: If no reduction is to take place, e.g. in a low energy
house.
Heating mode
The heating circuits (HK) are constantly held at the comfort tem-
perature (applies to HK 1 and HK 2).
f Set the comfort temperature for the relevant heating circuit
DHW heating
DHW heating takes place according to the specified seven-day pro-
gram times. The heat pump switches between comfort tempera-
ture and ECO temperature. Within the selected seven-day program
times, the heat pump heats to comfort temperature.
f Set the comfort temperature under SETTINGS / DHW / DHW
f Set the ECO temperature under SETTINGS / DHW / DHW TEM-
f Set the times under PROGRAMS / DHW PROGRAM.
4.4.4 ECO MODE
Purpose: If for a short period there is nobody in the building,
e.g. during a weekend break.
Heating mode
The heating circuits (HK) are constantly held at the ECO tempera-
ture (applies to HK 1 and HK 2).
f Set the ECO temperature for the relevant heating cir-
DHW heating
DHW heating takes place according to the specified seven-day pro-
gram times. The heat pump switches between comfort tempera-
ture and ECO temperature. Within the selected seven-day program
times, the heat pump heats to comfort temperature.
f Set the comfort temperature under SETTINGS / DHW / DHW
cuit under SETTINGS / HEATING / HEATING CIRCUIT / ECO
TEMPERATURE.
relevant heating circuit.
TEMPERATURES / COMFORT TEMPERATURE.
PERATURES / ECO TEMPERATURE.
under SETTINGS / HEATING / HEATING CIRCUIT/COMFORT
TEMPERATURE.
TEMPERATURES / COMFORT TEMPERATURE.
PERATURES / ECO TEMPERATURE.
cuit under SETTINGS / HEATING / HEATING CIRCUIT / ECO
TEMPERATURE.
TEMPERATURES / COMFORT TEMPERATURE.