11. Technical data
Rated Voltage:
Frequency range:
Input resistance:
Current peak value:
Surge voltage strenght:
Indicator group:
Indication:
Limit U t :
Measurement ranges / Accuracy:
On-time:
Self-test:
Construction:
Operating temperature:
Power supply:
Design:
Standards:
Test label:
Dimensions/weight:
50 ... 36000 V AC / DC
0 ... 200 Hz
119 MΩ
< 0.4 mA at 36000 V
> 300 kV (test report available)
I and III
red LED for voltage > Limit U t
green LED for standby / absent of voltage
360° LED light-stripe red / green
two-line LCD with backlight red / green for indication of voltage,
frequency, type of voltage, and battery condition
acoustic signal at > Limit U t
The value of the response voltage Ut is labelled on the name plate.
50 ... 1000 V AC/DC ± 5% + 10 digits, resolution 1 V
1.00 ... 9.99 kV AC/DC ± 5% + 10 digits, resolution 10 V
10.0 ... 36.0 kV AC/DC ± 5% + 10 digits, resolution 100 V
automatic range switching
15 min
function, grounding and protective resistors
for indoor and outdoor installations,
IP 65, device can be used in moist environments
–15°C ... + 55°
6 x AA 1,5 V - IEC LR6 alkali-manganese or FR6 Lithium battery
multi-stage battery indicator
two-pole voltage tester with fixed connection to ground
two-piece high-tension test probes, screwable, made of double-walled
GRP-tube with moulded resistor decade display part made of impact
resistant, dust proof plastic casing IP 65 with unbreakable display cover
10 m PUR cable with universal clip for condutor bars and
fixed ball points up to 25 mm
EN/IEC 61243-2 high voltage tester
EN/IEC 60071 surge voltage strength
further applied standards:
EN/IEC 61010 and EN 50110-1
(further details see risk analysis)
date of the next examination on the sticker
repeated inspection at least every 6 years
2.3 kg / approx. 1430 x 100 x 100 mm
Transportation length demounted 900 mm
19