10 Assembly and installation
10.6 Assembling the stroke limiter (linear actuator)
7.1
1
2
3
4
7.2
5
Option1
9
8
6
1
Stroke limiter
2
Nut
3
1)
Seal
4
1)
Washer
5
2)
Distance piece
6
Actuator spindle
1) Only available for valves with the NO and DA control functions.
2) Only included in required mounting kits. The design depends on the valve.
GEMÜ 1235 / 1236
24V / IO-Link, 3E, 4E
1. Screw distance piece 5 onto/into actuator spindle 6.
2. Move the actuator to the closed position.
3. Insert the O-ring 7.1 in the stroke limiter 1.
4. Insert the O-ring 7.2 in the washer 4.
5. Screw stroke limiter 1 with nut 2, seal 3 and washer
4 into the actuator opening.
6. Set stroke limiter 1 to the required stroke.
7. Make sure that the minimum stroke is reached.
8. Secure stroke limiter 1 with nut 2.
5
Option2
Key
7.1
1)
O-ring
7.2
1)
8
Protective cap
9
Position indicator
10
Operating bush
11
Spindle
12
Travel sensor
52 / 76