Reset
Disconnect the terminals Ta and Tb
at the BSG, then disconnect the
power. When restoring the power,
hold the "Prog. Mode" button
down for 3 seconds. Now wait until
the BSG has fully run up, and only
then reassign the terminals Ta and
Tb. The BSG will the start to reboot
again. This completes the reset
process.
Exchanging the BTLM 650-.../
BTLE 050-...
When exchanging the BTLM 650-... /
BTLE 050-... , the call buttons must
always be completely repro-
grammed.
Wiring diagram
AS-TH-1/1
Remark relevant to the circuit
diagram
a) Up to max. 4 illuminated Vario
modules, the TR 602-... can be
omitted, b and c are connected at
the NG 602-...
Commissioning
and programming
Commissioning
Setting the address
Fig. 1
Each address may be set only once
in the system.
System start
Fig. 2 and 3
LED is flashing until the system is
operational.
Programming
Switching on the programming
mode
Fig. 4
Activating the BTLM
Fig. 5a
Activating the BTLE
Fig. 5b
Activating the BT
Figs. 6 to 8
Assigning the call buttons
Fig. 9 and 10
Checking
Figs. 11 to 14
!
Only press the call button
briefly (< 2 secs.) as otherwise
the call button will be deleted again.
Parallel operation of the 2 BTs
Activating the 1st BT: Figs. 15 to 17
Activating the 2nd BT: Figs.18 to 20
Assigning call buttons
Fig. 21 and 22
Switching off programming
mode
Fig. 23 and 24