Herunterladen Diese Seite drucken

Endress+Hauser Gammapilot M FMG60 PROFIBUS PA Betriebsanleitung Seite 49

Radiometrische messtechnik
Vorschau ausblenden Andere Handbücher für Gammapilot M FMG60 PROFIBUS PA:

Werbung

Gammapilot M FMG60 PROFIBUS PA
Endress+Hauser
Parameter
Menü-Posi-
tion
Input Level
(*42)
Linearisation Start Stop
(*43)
Normal. Pulse Rate
(*44)
Unit Selection
(*45)
Customer Unit
(*46)
Linearisation Concentr.
(*47)
Table Number Con-centr. (*48)
Input Density
(*49)
Input Concentr.
(*4A)
Lin. Next Point
(*4B)
Gammagr. Detect.
(*50)
Span Time
(*51)
Gammagr. Sensitivity
(*52)
Gammagr. Output
(*53)
Gammagr. Hold Time
(*54)
Gammagr. Counter
(*55)
Gammagr. Counter Reset (*56)
PA Slave Address
(*60)
PA Ident Number Sel.
(*61)
Set Unit To Bus
(*62)
AI Out Value
(*63)
AI Out Status
(*64)
Sim. Level Mode
(*65)
Sim. Density Mode
(*65)
Sim. Concentr. Mode
(*65)
Sim. Value Level
(*66)
Sim. Value Pulse Rate
(*66)
Sim. Value Density
(*66)
Sim. Value Concentr.
(*66)
2nd Cyclic Value
(*67)
Select Main Value
(*68)
Language
(*92)
Back To Home
(*93)
No. of Decimals
(*95)
Sep. Character
(*96)
Display Test
(*97)
Present Error
(*A0)
Last Error
(*A1)
Clear Last Error
(*A2)
Reset
(*A3)
Unlock Parameter
(*A4)
Pres. Avg. Pulse Rate
(*A5)
Slot Index Size [bytes] Type
1
202
4
FLOAT
1
203
2
ENUM
1
204
4
INT32
1
205
2
ENUM
1
206
2
ENUM16 X
1
207
2
ENUM
1
208
1
UINT8
1
209
4
FLOAT
1
210
4
FLOAT
2
233
2
ENUM
1
220
2
ENUM
1
221
2
UINT16
1
222
1
UINT8
1
223
2
ENUM
1
224
2
UINT16
1
225
2
UINT16
1
226
2
ENUM
1
230
1
UINT8
1
231
2
ENUM
1
232
2
ENUM
1
233
4
FLOAT
1
234
1
UINT8
1
235
2
ENUM
1
236
2
ENUM
1
237
2
ENUM
1
238
4
FLOAT
1
239
4
INT32
1
240
4
FLOAT
1
241
4
FLOAT
1
242
2
ENUM
1
243
2
ENUM
1
245
2
ENUM
1
246
2
INT16
1
247
2
ENUM
1
248
2
ENUM
1
249
2
ENUM
2
0
2
UINT16
2
1
2
UINT16
2
2
2
ENUM
2
3
2
UINT16
2
4
2
UINT16
2
5
4
INT32
Bedienung
Read Write Storage Class
X
X
static
X
X
static
X
X
static
X
X
static
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
dynamic
X
X
static
X
X
static
X
X
static
X
X
static
X
dynamic
X
dynamic
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
X
static
X
dynamic
X
dynamic
X
X
static
X
X
static
X
X
static
X
dynamic
49

Werbung

loading