Herunterladen Diese Seite drucken

Miele PDR 914 HP Installationsplan Seite 22

Gewerblicher wärmepumpentrockner
Vorschau ausblenden Andere Handbücher für PDR 914 HP:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
en - Technical data
Sound power level
Average heat dissipation rate into the room
Permissible ambient temperature range
Fixing options
Fixing without plinth
Tensioning strips
Wood screws DIN 571 (Ø × length)
Plugs (Ø × length)
If the tumble dryer is being installed without a plinth, fixing it in place is recommended.
Fastenings for floating screed must be supplied by the customer on site.
Fixing to concrete plinth
Tensioning strips
Wood screws DIN 571 (Ø × length)
Plugs (Ø × length)
If the tumble dryer is being fixed to a concrete plinth on site, fixing in place is absolutely essential.
Fastenings for floating screed must be supplied by the customer on site.
Options/Accessories
Concrete base (on site)
Minimum width
Recommended height
Minimum height
Minimum depth
The quality of the concrete and its strength must be assessed according to the machine load. The on-site concrete plinth must be fixed
adequately to the floor.
22
Quantity
2
2
2
Quantity
2
2
2
62
3.9 MJ/h
10–40 °C
Screw size
6×40 mm
10×50 mm
Screw size
6×40 mm
10×50 mm
1050 mm
100 mm
50 mm
1200 mm