It is advisable to connect the product via a suitably rated plug and
socket in accordance with IEC-60309, otherwise for a hardwired con-
nection an all pole means of isolation must be installed at the site.
An isolation device is a switch which ensures a contact opening of
more than 3 mm. These include circuit breakers, fuses and contact-
ors (IEC/EN 60947).
If the mains supply cannot be permanently disconnected, the isola-
tion device (including plug and socket) must be safeguarded against
being switched on either unintentionally or without authorisation.
The tumble dryer must not be connected to devices such as timers
which would switch it off automatically.
If local regulations require that a residual current device (RCD) is in-
stalled, a type B residual current device (sensitive to universal cur-
rent) must be used.
If local and national installation specifications require equipotential
bonding, good galvanic contact must be guaranteed. Equipotential
bonding must have an earth current rating > 10 mA.
 Loud noises and risk of damage due to incorrect phase connec-
tion on heat-pump dryers.
An incorrect phase position causes a lot of noise in tumble dryers
with heat pumps and can cause damage to the compressor.
When connecting a heat-pump dryer to the power connection, en-
sure the correct phase position according to the wiring diagram.
Peak-load negotiation
The heat-pump dyer can be connected to peak-load negotiation if
this is required. However, this is not essential, as the heat-pump dryer
has been designed for very low energy consumption.
Depending on the function, switching off the appliance externally
during the drying process when the heat-pump is in use can re-
duce the service life of the appliance.
Please note that if it is connected to peak-load negotiation, the
heat-pump dryer must not be switched off.
Information on operating status is made available via the
Miele peak-load interface. Please note that the energy requirement
of all appliances that cannot be switched off in the energy manage-
ment system must be stored by the control system.
Air intake vent
The air supply for the cooler is drawn in through the air intake vent
on the front of the machine directly from the room in which the dryer
is installed.
en - Installation notes
15