Herunterladen Diese Seite drucken

HBM C16i-Serie Gebrauchs- Und Wartungsanleitung Seite 28

Digitale wägezelle

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

28
ATTENTION
Before loading the bridge for the first time by driving on it with a truck /
vehicle, do in any case adjust the lateral stops such that the load cells'
permissible skewings or lateral displacements of the load introduction
parts are not exceeded (see Dimensions = Chapter 12). Otherwise, the
load cells or load introduction parts might be damaged.
ATTENTION
Adjust lateral stops of
the weighing platform:
NOTE
Type C16i... load cell is metal-clad by laser-welding and made from rust-
proof materials. Therefore they comply with protection class IP68 ac-
cording to EN 60 529 (IEC 529) under the stated test conditions (see
Specifications).
In general, the load cell permit steam jet cleaning. However, the conditions for
max. pressure, temperature, etc., stated in the EN 60 529 for protection class
IP69K, must be observed.
When EPO3/50t, C16/EPU44A or C16/ZOU44A mounting parts from HBM are
used, the integral rotation stop device, described in chapter 8 "Mounting", can
be used. With customized mounting parts, HBM provides drawings showing
the position and mounting of the rotation stop. In this case, special attention
must be paid to the observance of the tolerances stated for the dowel pin
position, to prevent the load cells from being damaged.
Only when the HBM specifications are followed will the HBM warranty
for the product be valid.
The C16/ZOU44A load introduction parts accessory kit can be used as an
economical alternative for load cells with nominal loads up to 60 t. In this
case, however, the maximum load for each load cell must not exceed
40 t.
HBM
C16i...
A1461--1.2 de/en/fr

Werbung

loading

Diese Anleitung auch für:

C16/zou44aC16/epu44a