Modes of operation
5.9 Self-test
The self-test checks the connection and the function of the
connected 6593-.../STD-500MA central dimmers.
• Push pin
Afterwards, the following signals are transmitted con-
tinuously on both channels:
- D1: soft ON, 1 second maximum brightness level
soft OFF, 1 second pause, then
- D2: as above for D1
• Push pin
5.10 Reset
• Push pin
- All the stored values are deleted
- All the functions are deactivated
- Operation via pushbutton/switch is not possible
• Push pin
the previous functions.
on the coding switch to "on".
back to "off" to end the self-test.
on the coding switch to "on":
back to "off" to end the reset and re-activate