Herunterladen Diese Seite drucken

Kärcher Inno-Foam-Set Bedienungsanleitung Seite 9

Vorschau ausblenden Andere Handbücher für Inno-Foam-Set:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
For other high-pressure cleaners
without hose reel
Flow volume
over 500 to 600 l/h
(over 8.3 to 10 l/min)
over 600 to 700 l/h
(over 10 to 11.8 l/min)
over 700 to 1000 l/h
(over 11.8 to 16.6 l/min)
over 1000 to 1300 l/h
(over 16.6 to 21.6 l/min)
Install the injector
– The injector suctions cleaning agents
and mixed them into the water stream.
– This suction effect will only be created if
the included round jet nozzle is integrat-
ed in the foam nozzle.
 Switch off the high pressure cleaner.
 Interrupt current and water inflow.
 Activate trigger gun until device is pres-
sure-less.
Unheated appliances without hose drum
1 O ring
2 Injector
3 Injector insert
 Slide O rings onto the injector insert and
coat lightly with silicone grease.
 Slide injector insert into the injector and
Order num-
ber
2.111-009.0
2.111-018.0
1 High pressure hose
2 Detergent suction hose with filter
2.111-019.0
3 Injector
4 High-pressure outlet
2.111-020.0
 Unscrew the high pressure hose from
 Screw the injector to the high-pressure
 Screw the high-pressure hose to the in-
 Pass the detergent suction hose into a
HD 10/25 SX, HD 13/18 SX (with hose
reel)
1 Screw
2 Cover
 Loosen screws.
 Remove the appliance cover.
– 2
EN
tighten fingertight using a 12x2 flat tip
screwdriver.
the high pressure outlet.
outlet and tighten the union joint (max.
10 Nm).
jector outlet and tighten fingertight.
detergent canister or into the detergent
tank of the high-pressure cleaner.
9

Werbung

loading

Diese Anleitung auch für:

Easy-foam-set