After unpacking it, carefully clean all the cooler, using warm water
and neutral soap at 5%, then dry it with a soft cloth: use only specific
products for the glasses avoiding water which can leave calcareous
residues.
Keep a distance from the wall at least of 10 cm.
Please settle the adjustable feet 10 mm lower than the level face of
small rollers (EIS 104).
Cabinet must be installed on a perfectly even surface,
far away from any heat source (radiators, stoves, etc)
including sun rays.
Good running of the cabinet can be compromised
in cases where the airflow is
ventilators, air conditioning outlets, etc).
Smooth running of the cabinet is assisted when
sufficient air is permitted to flow through the bottom
of the unit; it is very
base are kept uncovered.
Do not expose the cabinet to rain. Install and
position the unit in such a way so as to allow easy
access to the power socket.
THE REFRIGERATOR IS NOT SUITABLE FOR
WORKING IN DANGEROUS ENVIRONMENT
WITH RISK OF FIRE, EXPLOSIONS OR
RADIATIONS.
Operation is regular with ambient temperature
indicated on technical data plate placed in the tank.
PUTTING INTO OPERATION
Check that the voltage on the identification plate is the same as that
of the network. THE ELECTRICAL SUPPLY LINE TO WHICH
THE REFRIGERATOR WILL HAVE TO BE CONNECTED
IS TO BE PROTECTED BY A VERY SENSITIVE
DIFFERENTIAL SWITCH (Rc = 16A, Dc = 30mA); IT IS
ALSO TO BE LINKED TO THE GENERAL EARTHING
PLANT. Earthing is necessary and compulsory by law.The
manifacturer disclaims all responsability for any damage to people
or things due to incorrect observance of this rule.Do not use any
multiple jack.
On mmodel EIS 214, After switching on or after every thermostatic
pause, one of 2 compressors will start 30 seconds later than the
other.