DOOR REGULATION
This unit is equipped with sliding doors. The levelling
operation is very important: a bad levelling can cause
a fold of the door frames when the loading operation
is finished. The cabinet must be installed on an even
surface; it is necessary to settle the sliding doors so
that they will be parallel. In order to do this you can
adjust the wheel on the bottom (A-B);for example if
there is a gap upwards you can raise the wheel A or
pull down the wheel B. To adjust a wheel it is
necessary at first to unscrew the screw Nr.1; than you
can screw down or unscrew the screw Nr. 2 if you
want to pull down or to raise the wheel. When the
desired position is reached screw down the screw 1
again. To remove the door, you must unscrew the
upper lines; push up the door and extact it.
A) Top neon tube starter (EIS 214)
B) Tank horizontal neon tube starter (EIS 214)
INFORMATIONS ABOUT SERVICE
TOP NEON TUBES REPLACEMENT
To replace top neon tubes proceed as follow:
-Extract the 2 side covers on the top.
-Remove the frontal panel.
-Rotate and extract the tubes from tube support.
REAR HANDLES MOUNTING
In order to obtein a right working of the cabinet, it's
necessary to mount on the rear side two handles A
fixed by screws B 5.5x16 TEFR. The handles can
be use either to move the cabinet or as spacer from
the wall.