Key/Display
Operation
Setting the Timer function
The device's operating logic allows the user to freely programme when it is to switch on or off.
While the cooler-radiator is on, you can programme it to switch off by pressing the Timer key and then setting the
number of hours (from 1 to 24) after which the device is to switch to stand-by.
When the cooler-radiator is off, you can programme it to switch on by pressing the Timer key and then setting the
number of hours (from 1 to 24) after which the device is to switch on.
Next, press the enter key.
Touch-screen display keylock
To lock the keys, hold the Timer symbol on the touch-screen display pressed for 3 seconds. The keylock will
prevent the user from enabling or disabling any function on the display. The stand-by symbol flashes intermittently
every second.
To turn off the key-lock, press the Timer symbol again for 3 seconds on the touch-screen display.
Any selection from the remote control will deactivate the key-lock!
Alarms display
In the event of a malfunction, the display shows an alarm code.
The  device will nonetheless continue to perform certain functions
(see OPERATION column).
Alarm displayed
Cause
Room temperature probe (RT)
E1
failure.
E2
Internal battery probe IPT failure
E5
Indoor fan motor failure
Lack of communication with
E7
the display *
CP
Presence contact CP open
flashing
Incorrect water temperature
flashing
Incorrect water temperature
Operating the unit if the remote control is not available
If you lose the remote control, the batteries run out or the remote
stops working, you can be operate the device with the keys on the
touch-screen display on-board the machine.
4.4
Troubleshooting
For the user it is important to distinguish any malfunction or
performance levels that differ from the system's standard
operating values (see technical specifications). The most
common problems can be easily solved by the user by
performing certain simple tasks (see the Troubleshooting
paragraph), while some system alarms require that you
contact the Technical Customer Service.
Operation
It is possible to normally activate the Cooling, Dehumidification
and Heating modes.
It is possible to normally activate the Cooling, Dehumidification
and Heating modes.
You cannot activate any operating mode.
You cannot activate any operating mode.
The unit is enabled only if the contact is closed. Check the
connection of the terminals.
In heating mode, the water temperature is below 30 °C
In cooling mode, the water temperature is above 20 °C
Please keep in mind that any attempt by unauthorised staff to
repair the device automatically voids any form of warranty.