Spring clamps -AB+ and CP connection
The terminals intended for the electrical connections are
compatible with 0.2 to 1.5 mm² section rigid or flexible
cables, while if they are provided with lugs with plastic
collar, their maximum section is reduced to 0.75 mm².
For correct and secure connection follow the operations
below:
- strip the cable by 8 mm as shown below;
- if the cable is rigid you should be able to insert its end
easily, while if it is flexible you should use a pair of
EN
CP presence contact input connection
When the contact connected to the CP (ref. A) input is
closed, all the convectors connected will be switched off.
24
A
C
nose grippers;
- insert the cables completely and make sure they are
properly fixed by pulling them slightly;
To disconnect the cables use a screwdriver to press the
corresponding white notch (ref.C) and remove the
conductor.
8mm
0.2-1 mm
The input cannot be connected in parallel to one of another
electronic board (use separate contacts).
2