Key/Display
Operation
Power on/off
By pressing the appropriate key, you can switch the device off (standby) or on. The control panel has its own memory,
therefore no settings will be lost in case of shut-down or power outage. The key is used to activate or deactivate the
unit for short periods.
Cooling only mode
Ventilation only mode
When you enable this function, the device enable the fan and does not adjust the temperature or the humidity of the
air in the room. THE MODE allows you to set the fan speed
Heating only mode
Night comfort key
With the device switched on and the cooling or heating mode selected, pressing this key allows you to perform multiple
functions in order to maximise the quietness of the device, saving on electricity and optimally adjusting the temperature
for night comfort.
In this mode the fan is set to minimum speed.
This function should be activated just before falling asleep.
EN
This function is not available in the dehumidification only, ventilation only and automatic economy mode, and can be
excluded at any time (ideally when you wake up) by pressing the key again.
If you simultaneously set the Timer function, the device switches off after the preset time.
Airflow direction control
By pressing the appropriate key, you can set the constant oscillation of the air flow deflector, in which case the symbol
on the display is on, or lock it in any position.
Fan speed control
Repeatedly pressing this key will change the speed with the following sequence: Minimum, Medium, Maximum and
Automatic.
The higher the set speed, the higher the device's performance (but also the louder the noise). If you set the speed to
Automatic (you will notice the 3 speed bars slide on the display), the micro-processor will adjust the speed automatically
(the higher the difference between the room temperature and the set temperature, the higher the speed). The speed is
reduced automatically as the room temperature gradually reaches the set temperature. In dehumidification only mode
and night comfort mode, you cannot adjust the speed, as the unit can work only at low speed.
28
If you plan to keep the device out of service for a prolonged time, remember to deactivate it by disconnecting the
power or removing the power plug.
When this operating mode is enabled, the device dehumidifies and cools the room.
The temperature can be set between 16 and 31 °C. If the set temperature is lower than the room temperature,
after three minutes (at the most) the cooler-radiator will start running and the device begins to deliver cold air,
continuing to ventilate the room even if the device reaches the set-point.
When this operating mode is enabled, the device heats the room.
You can set the temperature between 16 and 31 °C and if the temperature is higher than room temperature, after
three minutes (at the most) the compressor goes off and the appliance begins to provide heat.
In cooling mode, the set temperature is increased by 1 °C after 1 hour and by 1 °C after 2 hours. After the second
hour, the temperature setting is not altered any more and after 6 more hours the device shifts to stand-by.
In heating mode, the set temperature is decreased by 1 °C after 1 hour and by 1 °C after 2 hours. After the
second hour, the temperature setting is not altered any more and after 6 more hours the device shifts to stand-by.
IMPORTANT: Never force the flow deflector manually to move it. In cooling and dehumidification mode, the flow
deflector's position is reset every 30 minutes in order to prevent the formation of dew.