Herunterladen Diese Seite drucken

Benning TA PV Bedienungsanleitung Seite 3

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.2 Connection to BENNING CM 10-PV
LOG
2 Sec
MIN
HFR
MAX
Inrush
Volt Sense
2 Sec
2 Sec
CM 10-PV
BENNING TA PV
TA PV
4.3 Connection to BENNING MM 10-PV
VoltSense
mV Ω
A
V
V
Volt
Sense
PV
PV
TRUE RMS
A
COM
MAX
600V CAT IV
10A
1000V CAT III
FUSED
BENNING TA PV
03/ 2020
BENNING TA PV
5. Technical data
-
Standard: EN 61010-031
PV-Strang
-
Maximum rated voltage (operating voltage) for test and measuring electrical
circuits, which are not directly connected to the mains:
1500 V AC/ 2000 V DC
-
Maximum rated voltage to earth (
suring electrical circuits, which are directly connected to the mains:
With push-on caps: 1000 V CAT III, 600 V CAT IV
Without push-on caps: 1000 VAC CAT II/ 1500 VDC CAT II
-
Length: 1.4 m
-
Protection class II (
-
Contamination class: 2
-
Ambient conditions:
Maximum barometric height for measurements: 2000 m
Temperature: 0 °C to + 50 °C, humidity 50 % to 80 %
6. Cleaning
Clean the exterior of the device with a clean dry cloth (exception: special cleaning
wipers). Do not use any solvents and/or abrasives to clean the measuring adapter.
7. Contact address
Benning Elektrotechnik & Elektronik GmbH & Co. KG
Service Center
Robert-Bosch-Str. 20
D - 46397 Bocholt
8. Environmental note
At the end of product life, dispose of the unserviceable device via
appropriate collecting facilities provided in your community.
PV-Strang
Benning Elektrotechnik & Elektronik GmbH & Co. KG
Phone: +49 (0) 2871 - 93 - 0 • Fax: +49 (0) 2871 - 93 - 429
5
Q
) and measuring category for test and mea-
), continuous double or reinforced insulation
&
Münsterstraße 135 - 137
D - 46397 Bocholt
www.benning.de • E-Mail: duspol@benning.de