17 Troubleshooting
17 Troubleshooting
17.1
Troubleshooting the Blower and Battery
Fault
LEDs on the
battery
The blower does
1 LED flashing
not start when
green.
switched on.
1 LED emits
red light.
3 LEDs flash
red.
3 LEDs light up
red.
4 LEDs
flash red.
The blower turns
3 LEDs light up
off while in ope‐
red.
ration.
The blower ope‐
rating time is too
short.
18 Specifications
18.1
STIHL BGA 300.1 Blower
– Permitted batteries:
– STIHL AR L
0458-724-9602-A
Cause
State of charge of the
battery is too low.
The battery is too
warm or too cold.
There is a fault in the
blower.
The blower is too
warm.
There is a fault in the
battery.
There is a break in the
electrical connection
between the blower
and the battery.
The blower or the bat‐
tery is damp.
Trigger is pressed
before operating the
release slide.
The blower is too
warm.
There is an electrical
fault.
The battery is not fully
charged.
The battery service
life has been excee‐
ded.
– STIHL AP together with the ADA 1000 dual
– Blowing force: 26 N
– Maximum air velocity: 86 m/s
– Average air velocity: 72 m/s
Remedy
► Charge battery as described in the User
Manual for chargers STIHL AL 101, 301,
301-4, 500.
► Remove the battery.
► Allow the battery to cool down or warm
up.
► Remove battery and reinsert it.
► Turn on blower.
► If 3 LEDs continue to flash red: Do not
use the blower and contact your STIHL
dealer for assistance.
► Remove the battery.
► Allow the blower to cool down.
► Remove battery and reinsert it.
► Switch on blower.
► If 4 LEDs continue to flash red: Do not
use the battery; contact a STIHL authori‐
zed dealer.
► Remove the battery.
► If the blower still does not start when tur‐
ned on: Clean the contacts of the con‐
nector as described in the user manual
for the STIHL AR L battery or in the
STIHL ADA 1000 double-battery com‐
partment adapter.
► Allow blower or battery to dry.
► Turn on the blower as described in this
user manual.
► Remove the battery.
► Allow the blower to cool down.
► Remove the battery and reinsert it.
► If the blower still does not start when tur‐
ned on: Clean the contacts of the con‐
nector as described in the user manual
for the STIHL AR L battery or in the
STIHL ADA 1000 double-battery com‐
partment adapter.
► Switch on the blower.
► Fully charge battery as described in the
User Manual for the STIHL AL 101, 301,
301-4, 500 chargers.
► Replace battery.