Herunterladen Inhalt Inhalt Diese Seite drucken

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 13
DECLARATION OF CONFORMITY
This product is marked
– Low voltage no. 2006/95/CE. (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012
+ A1:2006 + A2:2009 con EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 +
A15:2011).
– Electromagnetic compatibility no. 2004/108/CE, 92/31 EEC and 93/68 EEC. (Standard: EN55014-1 (2006) + A1(2009)
+ A2(2011), EN 55014-2 (1997) + A1(2001) + A2 (2008), EN 61000-3-2 (2006) + A1(2009) + A2(2009),
EN 61000-3-3 (2008)
– RoHS2 no.2011/65/EU.
– Regulation (EU) no. 206/2012, of 6 march 2012, concerning the specifications for ecodesign requirements of air
conditioners and fans.
– Regulation (EU) no. 626/2011, of 4 may 2011, concerning the labeling indicating the energy consumption of air
conditioners.
This declaration will become void in case of misuse and/or non observance though partial of manufacturer's installation
and/or operating instructions.
í Cooling Maximum conditions
Outdoor temperature :
Room temperature :
í Cooling Minimum conditions
Outdoor temperature :
Room temperature :
Tools required for installation (not supplied)
1.Standard screwdriver
2.Phillips head screwdriver
3.Knife or wire stripper
4.Tape measure
5.Level
6.Sabre saw or key hole saw
7.Hacksaw
8. Core bits ø 8
INSTALLATION INSTRUCTIONS
as it satisfies Directives:
OPERATING LIMITS
43°C D.B.
32°C D.B. / 23°C W.B.
–15°C D.B.
10°C D.B. / 6°C W.B.
19.Hammer
10.Drill
11. Tube cutter
12.Tube flaring tool
13.Torque wrench
14.Adjustable wrench
15.Reamer (for reburring)
16.Hex. key
37.4255.119.01
- Split system air conditioner -
í Heating Maximum conditions
Outdoor temperature :
Room temperature :
í Heating Minimum conditions
Outdoor temperature :
Room temperature :
Model Combinations:
SEE CATALOGUE
Power Supply:
220 - 240 V ~ 50 Hz
REGULATION (EU) No. 517/2014 - F-GAS
The unit contains R410A, a fluorinated greenhouse gas with
a global warming potential (GWP) of 2087.50. Do not
release R410A into the atmosphere.
01/2017
24°C D.B. / 18°C W.B.
27°C D.B.
–15°C D.B.
5°C D.B.
EG
I
F
D
E
P
GR

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Argo AFIBS11DC

  • Seite 1 INSTALLATION INSTRUCTIONS - Split system air conditioner - DECLARATION OF CONFORMITY This product is marked as it satisfies Directives: – Low voltage no. 2006/95/CE. (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012 + A1:2006 + A2:2009 con EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011).
  • Seite 2: Special Precautions

    IMPORTANT! • Ground the unit following local electrical codes. • The Yellow/Green wire cannot be used for any connection Please read before installation different from the ground connection. • Connect all wiring tightly. Loose wiring may cause This air conditioning system meets strict safety and operating overheating at connection points and a possible fire standards.
  • Seite 3 Installation site selection - Indoor unit • Select a sufficiently strong location to support the weight AVOID of the unit. • Direct sunlight. • Select a location where tubing and drain hose have the • Nearby heat sources that may affect unit performance. shortest run to the outside.
  • Seite 5: Istruzioni Di Installazione

    ISTRUZIONI DI INSTALLAZIONE - Condizionatore d’aria Split System - DICHIARAZIONE DI CONFORMITÀ Questo prodotto è marcato in quanto conforme alle Direttive: – Bassa Tensione n. 2006/95/CE (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012 + A1:2006 + A2:2009 with EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011).
  • Seite 6 IMPORTANTE! • Eseguire la messa a terra dell’unità secondo le norme elettriche locali. Leggere prima di iniziare l’installazione • Il conduttore giallo/verde non può essere utilizzato per collegamenti diversi dalla messa a terra. Questo sistema di condizionamento deve seguire rigidi •...
  • Seite 7 Scelta del luogo di installazione unità interna resistente da sostenere il peso dell’unità. EVITARE • Scegliere una posizione in modo che la distanza tra le • L’esposizione diretta al sole. due unità sia la minore possibile. • La vicinanza a fonti di calore che possono danneggiare •...
  • Seite 9: Declaration De Conformité

    NOTICE D’INSTALLATION - Climatiseur split - DECLARATION DE CONFORMITÉ Ce produit est marqué puisque il est conforme aux Directives: – Basse Tension n° 2006/95/CE. (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012 + A1:2006 + A2:2009 with EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011).
  • Seite 10 IMPORTANT! • Effectuez la mise à la terre de l'appareil en respectant les réglementations électriques locales. Veuillez lire ce qui suit avant de commencer • Le câble jaune/vert ne peut en aucun cas être utilisé pour Ce système de conditionnement de l'air répond à des toute autre connexion que celle de la mise à...
  • Seite 11 Choix de l'emplacement d'installation - Appareil intérieur RECHERCHEZ • Un emplacement approprié à partir duquel l'ensemble de la EVITEZ pièce peut être climatisé de manière uniforme. • L'exposition directe au soleil. • Un emplacement suffisamment solide pour supporter le poids •...
  • Seite 13: Konformitätserklärung

    INSTALLATIONSANLEITUNGEN - Zweirohrsystem-Klimaanlage - KONFORMITÄTSERKLÄRUNG Dieses Produkt ist mit -Zeichen gekennzeichnet, weil es den folgenden Richtlinien entspricht: – Niederspannungsrichtilinie 2006/95/CE. (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012 + A1:2006 + A2:2009 with EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011).
  • Seite 14: Besondere Vorsichtsmassnahmen

    WICHTIG! Tod verursachen. • Erden Sie das Gerät gemäß den örtlich zutreffenden Bitte vor Arbeitsbeginn lesen Vorschriften. Diese Klimaanlage entspricht strengen Sicherheits- und • Das Gelbe/Grüne Kabel ist für die ausschließliche Betriebsnormen. Verwendung als Erdleitung. • Verbinden Sie Kabel fest miteinander. Lockere Für den Installateur oder Bediener dieser Anlage ist es Verbindungen können...
  • Seite 15: Begrenzung Der Verrohrungslänge Und Des Erhöhungsunterschieds

    Wahl des Installationsortes - Innenraumgerät • Wählen Sie eine Stelle, an der der Boden das Gewicht des VERMEIDEN SIE Gerätes tragen kann. • Direkte Sonneneinstrahlung. • Wählen Sie eine Stelle, von der aus die Rohre und der • Wärmequellen in der Nähe des Gerätes, die dessen Wasserablaufschlauch den kürzesten Weg nach darußen Leistungsfähigkeit beeinflussen könnten.
  • Seite 17: Declaracion De Conformidad

    INSTRUCCIONES DE INSTALACION - Acondicionador de aire Split System - DECLARACION DE CONFORMIDAD Este Producto está marcado porque responde a las Directivas: – Baja Tensión n° 2006/95/CE. (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012 + A1:2006 + A2:2009 with EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011).
  • Seite 18: Precauciones Especiales

    ¡IMPORTANTE! • Realizar la puesta a tierra de la unidad siguiendo las normas eléctricas locales. Leer antes de empezar la instalación • El conductor amarillo/verde no se puede utilizar para conexiones que no sean la de tierra. Este sistema de acondicionamiento cumple medidas rígidas •...
  • Seite 19 Dónde instalar la unidad interior • Elegir una posición adecuada desde la que se llegue a todos los rincones. EVITAR • Controlar que el lugar de apoyo es lo suficientemente • La exposición directa al sol. resistente como para soportar el peso de la unidad. •...
  • Seite 21: Instruções De Instalação

    INSTRUÇÕES DE INSTALAÇÃO - Sistema de ar condicionado de Unidades Separadas - DECLARAÇÃO DE CONFORMIDADE Este produto tem a marca porque responde às Directrizes: – Baixa tensão N° 2006/95/CE. (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012 + A1:2006 + A2:2009 with EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 + A15:2011).
  • Seite 22 IMPORTANTE ! • Ligue a unidade à terra seguindo as normas locais de eletricidade. Queira ler antes de colocar a unidade em funcionamento • O fio AMARELO/VERDE só deve ser usado para ligação Este sistema de ar condicionado satisfaz padrões rigorosos à...
  • Seite 23 Escolha do Local de Instalação da Unidade para Interior • Selecionar uma posição apropriada a partir da qual todos os cantos da sala possam ser uniformemente arrefecidos. EVITE • Escolher um local onde o piso seja suficientemente forte • A luz direta do sol. para poder suportar o peso da unidade.
  • Seite 25 O O D D H H G G I I E E S S T T O O P P O O Q Q E E T T H H S S H H S S - D D i i a a i i r r o o u u v v m m e e n n e e " " m m o o n n a a v v d d e e " " k k l l i i m m a a t t i i s s m m o o u u v v - D D H H A A W W S S H H S S U U M M M M O O R R F F W W S S H H S S To proi>ov n autov fev r ei to shv m a diov t i antapokriv n etai sti"...
  • Seite 26 S S H H M M A A N N T T I I K K O O ! ! • G G e e i i w w v v s s t t e e t t o o s s u u v v s s t t h h m m a a s s u u v v m m f f w w n n a a m m e e t t o o u u " " i i s s c c u u v v o o n n t t e e " " topikouv " D D i i a a b b a a v v s s t t e e p p r r i i n n a a r r c c i i v v s s e e t t e e t t h h n n e e g g k k a a t t a a v v s s t t a a s s h h hlektrikouv "...
  • Seite 27 E E p p i i l l o o g g h h v v t t o o u u c c w w v v r r o o u u e e g g k k a a t t a a v v s s t t a a s s h h " " t t h h " " e e s s w w t t e e r r i i k k h h v v " " m m o o n n a a v v d d a a " " •...
  • Seite 28 INDOOR UNIT • UNITÁ INTERNA • UNITE INTERIEURE • INNENEINHEIT • UNIDAD INTERIOR • UNIDADE INTERIORE • E E S S W W T T E E R R I I K K H H M M O O N N A A D D A A Minimum operation and maintenance area.
  • Seite 29 Before installing the unit it is necessary to remove the front panel: - Open the air intake grille and remove it (detach the safety string). - Remove the front panel by loosening the 4 fixing screws. Prima di installare l’unità è necessario rimuovere il pannello frontale: - Aprire la griglia di aspirazione e rimuoverla (staccare la funicella di sicurezza).
  • Seite 30 Wall installation. Place the bracket to the wall and fix the central screw, level it and mark the other holes to drill as shown in the figure (2 holes are optional); fix completely the bracket. Hang the unit to the bracket, mark the holes to drill for the fixing of the unit. Installazione a parete.
  • Seite 31 Make the holes for the fixing of the unit. Running power electric cable (with a ground wire) between the two units (see the table of wire section). Check if the quantity and the rawl plugs type supplied are the proper ones for fixing the unit on the wall.
  • Seite 32 Remove the electrical box cover to operate on the terminal strip. Rimuovere il coperchio scatola componenti elettrici per accedere alla morsettiera. Enlever le capot de la boîte des composants électriques. Die Abdeckplatte des Klammbrettes entfernen. Quitar la tapa de la caja de los componentes eléctricos para acceder a la regleta de bornes.
  • Seite 33 Colocar el cable eléctrico y concitarlo al tablero de bornes (véase esquema de conexiones). Bloquear el cable a la abrazadera de la brida. ADVERTÊNCIA Controlar que los bornes de los cables estér bien sujetos en el tablero de bornes. De otro modo, podrían recalentarlo o provocar problemas en el funcionamiento del acondicionador con riesgo le incendio.
  • Seite 34 Fill the tank and verify that the condensate can flow correctly. Reassemble the front panel. Riempire la vaschetta quindi verificare il corretto scarico della condensa e rimontare il pannello frontale. Remplir le bac et vérifier que la sortie des condensat soit correcte. Remonter le panneau frontal.
  • Seite 35 SYSTEM WIRING DIAGRAM • COLLEGAMENTI ELETTRICI DEL SISTEMA • BRANCHEMENTS ELECTRIQUES DU SYSTEME • ELEKTRISCHE ANSCHLÜSSE DES SYSTEMS • CONEXIONES ELECTRICAS DEL SISTEMA • SISTEMA DE INSTALAÇÃO ELÉTRICA • H H L L E E K K T T R R I I K K H H S S U U N N D D E E S S H H T T O O U U S S U U S S T T H H M M A A T T O O S S LENGTH, SIZE WIRES AND DELAYED FUSE •...
  • Seite 36 Verbindungskabel B (ABGESCHIRMT): Elektrisches zweipoliges Abschirmkabel; Querschnitt und Länge des Kabels sind in der Installationsanleitungen der Ausseneinheit angezeigt. Das Kabel soll nicht leichter als H05VVC4V5-K -Typ sein (gemäß CEI 20-20 CENELEC HD21 ). Verbindungskabel C (mit Erdungsleitung): Elektrisches mehradriges Kabel; Querschnitt und Länge des Kabels sind in der Installationsanleitungen der Ausseneinheit angezeigt.
  • Seite 37 REMOTE CONTROL UNIT INSTALLATION • POSIZIONE DI INSTALLAZIONE TELECOMANDO • EMPLACEMENT DE LA COMMANDE A DISTANCE • POSITION DER FERNBEDIENUNG • POSICION DE INSTALACION DEL MANDO A DISTANCIA • POSIÇÃO DA INSTALAÇÃO DA UNIDADE DE CONTROLE REMOTO • Q Q E E S S H H T T O O P P O O Q Q E E T T H H S S H H S S T T H H L L E E C C E E I I R R I I S S T T H H R R I I O O U U REMOTE CONTROL UNIT INSTALLATION To ensure that the air conditioner operates correctly, DO NOT install the remote control unit in the following places: •...
  • Seite 38 WALL-MOUNTED POSITION • Momentarily place the remote control unit in the desired mounting position. • Verify that the remote control unit can operate from this position. • Fix the support at the wall with two screws and hang the remote control unit. POSIZIONE A PARETE •...
  • Seite 39 DEFAULT SETTING RESET - RESET IMPOSTAZIONI DI DEFAULT - REMISE A ZERO DES REGLAGES DE DEFAUT - ZURÜCKSETZEN AUF STANDARDEINSTELLUNGEN - RESTABLECER LA CONFIGURACIÓN PREDETERMINADA - RESTABLECIMENTO DAS CONFIGURAÇÕES DE FABRICA - ∂ ·Ó·ÊÔÚ¿ ÛÙ¿ÓÙ·ÚÙ Ú˘ıÌ›ÛÂˆÓ To operate the unit again with the default setting it is necessary to set the remote control as follows: Filter: ON Night Mode / High Power Mode: OFF Operation mode: AUTO...
  • Seite 40 Para restablecer las configuraciones predeterminadas de la unidad interior, ustedes tienen que regular el mando a distancia de la manera siguiente: Filter: ON Night Mode / High Power Mode: OFF Modo de funcionamiento: AUTO Flap: AUTO Temperatura seleccionada: 10°C Ahora, presionar simultáneamente los pulsadores del mando a distancia “FAN” y “I FEEL” durante mas de 5 segundos y soltarlos dirigiendo el mando a distancia hacia la unidad interior.
  • Seite 41 PUMP DOWN (See Installation Instruction of Outdoor Unit) Pump down means collecting all refrigerant gas in the “Pump down” significa: recuperar todo el gas system back into the outdoor unit without losing gas. refrigerante en la Unidad Exterior sin perder la carga Pump down is used when the unit is to be moved of del Sistema.
  • Seite 42 OUTDOOR/INDOOR UNIT REFRIGERANT CIRCUIT ADDRESS Indoor units that are part of a multisplit system must be properly configured to be able to communicate with the outdoor unit over different channels (Indoor A, Indoor B, etc...) of the communication bus. Each indoor unit address must correspond to the physical connection of the indoor unit to the outdoor unit refrigerant circuit, i.e.: Refrigerant Circuit A <-->...
  • Seite 43 (2) ADDRESS SETTING THROUGH REMOTE CONTROLLER (UP TO 8 INDOOR UNITS) Set the remote controller as shown in the table. BUTTON Indoor unit A: 11°C SETTING Indoor unit B: 12°C Indoor unit C: 13°C AUTO working mode (COOL - HEAT) Indoor unit D: 14°C set point Indoor unit E: 15°C...
  • Seite 44 (3) AUTOMATIC ADDRESSING PROCEDURE System requirements: Outdoor unit must have a recent firmware version that supports the automatic addressing procedure. Indoor units must have a recent firmware version that supports the automatic addressing procedure Dip-switch for communication address setting on the indoor unit (SW2) must be left to the factory default state, i.e. to the OFF position.
  • Seite 45 INDIRIZZO CIRCUITO REFRIGERANTE UNITA’ ESTERNA/INTERNA Le unità interne che fanno parte di un sistema multisplit devono essere opportunamente collegate in modo da comunicare con l’unità esterna su diversi canali (Indoor A, Indoor B, etc...) del bus di comunicazione. Ogni indirizzo dell’unità interna deve corrispondere a un collegamento fisico dell’unità interna con il circuito refrigerante dell’unità...
  • Seite 46 (2) IMPOSTAZIONE INDIRIZZI TRAMITE TELECOMANDO (FINO A 8 UNITA’ INTERNE) Impostare il telecomando come indicato in tabella. BUTTON Indoor unit A: 11°C SETTING Indoor unit B: 12°C Indoor unit C: 13°C AUTO working mode (COOL - HEAT) Indoor unit D: 14°C set point Indoor unit E: 15°C flap...
  • Seite 47 (3) PROCEDURA DI INDIRIZZAMENTO AUTOMATICO Requisiti di sistema: L’unità esterna deve avere una versione firmware recente che supporti la procedura di indirizzamento automatico. Le unità interne devono avere una versione firmware recente che supporti la procedura di indirizzamento automatico. I microinterruttori per l’impostazione dell’indirizzo di comunicazione sull’unità interna (SW2) devono essere lasciati nello stato di fabbrica, cioè...
  • Seite 48 ADRESSE DU CIRCUIT DE REFRIGERATION UNITE EXTERIEURE/INTERIEURE Les unités intérieures qui font partie d'un système multisplit doivent être configurés correctement pour communiquer avec l'unité extérieure sur plusieurs canaux (unité intérieure A, unité intérieure B, etc ...) du bus de communication. Chaque adresse de l'unité...
  • Seite 49 (2) REGLAGE DES ADRESSES AVEC LA TELECOMMANDE (JUSQU’A 8 UNITES INTERIEURES) Régler la télécommande comme indiqué dans le tableau. BUTTON Indoor unit A: 11°C SETTING Indoor unit B: 12°C Indoor unit C: 13°C AUTO working mode (COOL - HEAT) Indoor unit D: 14°C set point Indoor unit E: 15°C flap...
  • Seite 50 (3) PROCEDURE D’ADRESSAGE AUTOMATIQUE Exigences du système: L'unité extérieure doit avoir une version récente du firmware qui prend en charge la procédure d'adressage automatique. Les unités intérieures doivent avoir une version récente du firmware qui prend en charge la procédure d'adressage automatique.
  • Seite 51 AUSSEN/INNENEINHEIT-KÜHLROHRE ADRESSE Inneneinheiten, die Teil eines Multisplit-System sind, müssen korrekt konfiguriert sein, um mit der Außeneinheit über verschiedene Kanäle des Kommunikationsbusses zu kommunizieren (Inneneinheit A, Inneneinheit B, etc..). Jedes Inneneinheit-Adresse muß auf die physikalische Verbindung der Inneneinheit zur Außeneinheit Kältemittelkreislauf entsprechen, d.h.: Kältemittelkreislauf A <-->...
  • Seite 52: Adressen-Einstellung Mit Der Fernbedienung (Bis Zu 8 Inneneinheiten)

    (2) ADRESSEN-EINSTELLUNG MIT DER FERNBEDIENUNG (BIS ZU 8 INNENEINHEITEN) Stellen Sie die Fernbedienung ein, wie in der Tabelle gezeigt ist. BUTTON Indoor unit A: 11°C SETTING Indoor unit B: 12°C Indoor unit C: 13°C AUTO working mode (COOL - HEAT) Indoor unit D: 14°C set point Indoor unit E: 15°C...
  • Seite 53 (3) AUTOMATISCHE ADRESSIERUNG System Anforderungen: Die Außeneinheit muß eine aktuelle Firmware-Version haben, die die automatische Adressierung unterstützt. Die Inneneinheiten müssen eine aktuelle Firmware-Version haben, die die automatische Adressierung unterstützen. Die Schalter für die Kommunikation Adresseinstellung auf der Inneneinheit (SW2) müssen auf die Werkseinstellung belassen werden, d.h.
  • Seite 54 DIRECCION DEL CIRCUITO DE REFRIGERACIÓN UNIDAD EXTERIOR/INTERIOR Las unidades interiores que son parte de un sistema multisplit deben estar configurados correctamente para poder comunicar con la unidad exterior a través de diferentes canales (unidad interior A, unidad interior B, etc ...) del bus de comunicación.
  • Seite 55 (2) REGULACION DE LAS DIRECCIONES CON EL MANDO A DISTANCIA (HASTA 8 UNIDADES INTERIORES) Regular el mando a distancia como indicado en la tabla. BUTTON Indoor unit A: 11°C SETTING Indoor unit B: 12°C Indoor unit C: 13°C AUTO working mode (COOL - HEAT) Indoor unit D: 14°C set point Indoor unit E: 15°C...
  • Seite 56 (3) PROCEDIMIENTO DE DIRECCIONAMIENTO AUTOMÁTICO Requisitos del sistema: La unidad exterior debe tener una versión reciente de firmware que soporta el procedimiento de direccionamiento automático. Las unidades interiores deben tener una versión reciente de firmware que soporta el procedimiento de direccionamiento automático.
  • Seite 57 ENDEREÇO DE TUBAGENS DE REFRIGERANTE UNIDADE EXTERIOR/INTERIOR As unidades interiores que são parte de um sistema multi-split devem ser configuradas corretamente para poder comunicar com a unidade exterior através de diferentes canais de comunicação (Unidade interior A Indoor, Unidade interior B, etc ...). Cada endereço da unidade interior deve corresponder à...
  • Seite 58 (2) AJUSTAÇÃO DOS ENDEREÇOS COM O CONTROLE REMOTO (ATÉ 8 UNIDADES INTERIORES) Ajustar o controle remoto como mostrado na tabela. BUTTON Indoor unit A: 11°C SETTING Indoor unit B: 12°C Indoor unit C: 13°C AUTO working mode (COOL - HEAT) Indoor unit D: 14°C set point Indoor unit E: 15°C...
  • Seite 59 (3) PROCEDIMENTO DE ENDEREÇAMENTO AUTOMÁTICO Requerimentos do sistema: A unidade exterior deve ter uma versão recente do firmware que suporte o procedimento de endereçamento automático. As unidades interiores devem ter uma versão recente do firmware que suporte o procedimento de endereçamento automático. Os interruptores para configuração de endereço de comunicação da unidade interior (SW2) deve ser deixado para o estado padrão de fábrica, ou seja, para a posição OFF.
  • Seite 60 d d i i e e u u q q u u v v n n s s e e w w n n E E x x w w t t e e r r i i k k e e v v " " m m o o n n a a v v d d e e " " - - E E s s w w t t e e r r i i k k e e v v " " m m o o n n a a v v d d e e " " √È...
  • Seite 61 (2) R R Á Á Q Q M M I I S S H H D D I I E E U U Q Q U U N N S S E E I I S S M M E E T T H H L L E E C C E E I I R R I I S S T T H H R R I I O O ( ( e e v v w w " " 8 8 E E s s w w t t e e r r i i k k e e v v " " m m o o n n a a v v d d e e " " ) ) ƒ˘ıÌ›ÛÙÂ...
  • Seite 62 (3) ∞ÀΔ√ª∞Δ∏ ƒÀ£ªπ™∏ ¢π∂À£À¡™∏™ ∞ ·ÈÙ‹ÛÂȘ Û˘ÛÙ‹Ì·ÙÔ˜: ∏ Â͈ÙÂÚÈ΋ ÌÔÓ¿‰· ı· Ú¤ ÂÈ Ó· ¤¯ÂÈ Ì›· ÚfiÛÊ·ÙË ¤Î‰ÔÛË ˘ÏÈÎÔÏÔÁÈÛÌÈÎÔ‡ Ô˘ Ó· ˘ ÔÛÙËÚ›˙ÂÈ ÙËÓ ‰È·‰Èηۛ· ·˘ÙfiÌ·Ù˘ Ú‡ıÌÈÛ˘ ‰È‡ı˘ÓÛ˘. √È ÂÛˆÙÂÚÈΤ˜ ÌÔÓ¿‰Â˜ ı· Ú¤ ÂÈ Ó· ¤¯Ô˘Ó Ì›· ÚfiÛÊ·ÙË ¤Î‰ÔÛË ˘ÏÈÎÔÏÔÁÈÛÌÈÎÔ‡ Ô˘ Ó·...
  • Seite 63 REFRIGERANT CIRCUIT CHECK • CONTROLLO CIRCUITO REFRIGERANTE • CONTROLE DU CIRCUIT DE REFRIGERATION • NACHPRÜFUNG DER KÜHLROHRE • COMPROBACIÓN DEL CIRCUITO DE REFRIGERACIÓN • VERIFICAÇÃO DE TUBAGENS DE REFRIGERANTE • ¢π∞¢π∫∞™π∞ ƒÀ£ªπ™∏™ æÀ∫Δπ∫√À ∫À∫§øª∞Δ√™ 1. Power ON the system. 2. Set the remote controller of unit A as following (units B, C and D must be OFF): -Mode: COOLING -Filter: ON -Set-point: 32°C...
  • Seite 64 1. Encender el sistema. 2. Regular el mando a distancia de la unidad A como sigue (las unidades B, C y D tienen que ser apagadas): -Modo de funcionamiento: REFRIGERACIÓN -Filtro: ON -Temperatura: 32°C 3. Presionar los pulsadores FAN + IFEEL durante 5 segundos, dirigiendo el mando a distancia directamente al receptor del acondicionador.
  • Seite 65 MATCH BETWEEN REMOTE CONTROLLER AND INDOOR UNIT • ABBINAMENTO TRA TELECOMANDO E UNITA’ INTERNA • COMBINAISON ENTRE TELECOMMANDE ET UNITE INTERIEURE • KOMBINATION ZWISCHEN FERNBEDIENUNG UND INNENEINHEIT • COMBINACION ENTRE MANDO A DISTANCIA Y UNIDAD INTERIOR • COMBINAÇÃO ENTRE UNIDADE DE CONTROLE REMOTO E UNIDADE INTERIOR • d d i i e e u u q q u u v v n n s s e e w w n n ÙËϯÂÈÚÈÛÙ‹ÚÈÔ - - E E s s w w t t e e r r i i k k e e v v "...
  • Seite 66 Set SW1 as shown in the table. Impostare SW1 come indicato in tabella. Régler SW1 comme indiqué dans le tableau. Stellen Sie SW1 ein, wie in der Tabelle gezeigt ist. Regular SW1 como indicado en la tabla. Ajustar SW1 como mostrado na tabela. ƒ˘ıÌ›ÛÙÂ...
  • Seite 67 REMOTE CONTROLLER: HOW TO CHANGE FROM INFRARED TO WIRED • TELECOMANDO: TRASFORMAZIONE DA INFRAROSSI A FILO • TELECOMMANDE: TRANSFORMATION DE INFRAROUGE A FIL • FERNBEDIENUNG: WANDEL VOM INFRAROT ZU KABEL • MANDO A DISTANCIA: CAMBIO DE INFRARROJOS A CABLE • UNIDADE DE CONTROLE REMOTO: MUDANCA DE INFRAVERMELHO A FIO •...
  • Seite 68: Anschluss

    PREPARATION DE LA TELECOMMANDE Retirez le couvercle en plastique de la borne de la télécommande. ● Ouvrez le compartiment des piles, retirer les piles et régler les interrupteurs 5 et 6 en la position OFF. ● Fermez le compartiment des piles sans mettre les piles (la télécommande sera alimentée par le câble). ●...
  • Seite 69 PREPARAÇÃO DO CONTROLO REMOTO Remover a tampa de plástico da placa de terminais do controlo remoto. ● Abrir o compartimento das pilhas, remover as pilhas e colocar os microinterruptores 5 e 6 em posição OFF. ● Fechar o compartimento das pilhas sem voltar a colocar as pilhas (o controlo remoto será alimentado por um fio). ●...
  • Seite 72 Via Varese, 90 - 21013 Gallarate - Va - Italy Tel. +39 0331 755111 - Fax +39 0331 776240 www.argoclima.com...