Installation variants
 A
• Variant (a): Submerged pump installation
– The pump is positioned in the pond or basin.
– Water flow via the filter cage.
• Variant (b): Dry pump installation
– The pump is installed without the filter cage outside of the pond or basin but lower than the
water level.
– Water flow via a satellite filter or skimmer.
Installation and connection
The pump can be installed submerged (in water) or dry (outside the water).
The use of the pump is only permitted with observance of the specified water quality.
WARNING
The transformer is subject to dangerous voltage and must not be installed directly adjacent to
the water. Otherwise there is a risk of severe injuries or death by electrocution.
Install the transformer at a distance of at least 2 m from the water to ensure that it is pro-
tected against flooding.
NOTE
Electrical screw connections ...
must always be tightened hand-tight to ensure correct contact and so that they comply with
the protection class listed in the technical data.
are protected against splash water but must not be placed or submerged in water.
NOTE
If the pump is used for conveying excessively soiled water, the impeller unit will be subject to in-
creased wear and will require earlier replacement.
Thoroughly clean the pond or pool before installing the pump.
Install the pump at a raised level above the bottom. This reduces intake of muddy water.
Avoid direct sunlight on unit components that are not submerged, as they may overheat. If
necessary, use a protective cover.
EN
11