ADVANCED SETTINGS
To access the advanced configuration menu of the thermostat and Blueface Think follow the following steps:
Blueface
Press and hold
Think
Press once
From this menu you can change the system and zone parameters.
SYSTEM PARAMETERS
•
System address. Defines the number of the system within your installation. The value 1 is shown by default. The
system will display the available values (max = 247).
•
Temperature range. Selects the highest temperature in heating mode (19-30 ºC) and the lowest temperature in
cooling mode (18-26 ºC). It is also possible to disable some of the modes. The highest temperature by default is 30ºC.
The lowest temperature by default is 18ºC.
•
Type of opening. Use this to activate/deactivate the proportionality in the dampers of the system. The proportionality
adjusts in 4 steps the damper opening or shutting based on the temperature demand of the zone, regulating the flow.
It is configured as All/nothing by default.
•
Standby mode (only for Blueface thermostats). Configuration of the operating logic of the motorized elements when
there is no demand on the system. This is disabled by default.
•
Relay settings. Use this parameter to change the operation logic of the CMV/Boiler of the system main control board.
(By default CMV)
•
Q-Adapt (only for Think thermostats).
It allows you to select the flow control algorithm that best suits your installation. These are the available options:
-
Maximum: The system operates at maximum speed, irrespective of the number of zones.
-
Power: The speed of the system is higher than in standard mode to increase the flow.
-
Standard: Mode by default. The system automatically regulates the speed based on the number of zones.
-
Silence: The speed of the system is lower than in standard mode to reduce the noise.