TECHNICAL DATA
Working pressure 8 – 10 bar
Nominal voltage
a)
Frequency
Capacity at 8 bar (FAD) -40°C
b)
Working pressure
Rated current
Motor power
Air tank capacity
Air quality - filtration
Maximum operating pressure of safety
valve
Noise at 5 bar (L
)
pA
Operating mode
PDP drying performance at 7 bar
Dryer low pressure warning
Dryer high pressure warning
Dryer high dew point warning
Time to fill air tank from 0 to 7 bar
Dimensions (net)
w x d x h
c)
Net weight
a)
Specify the compressor version when ordering
b)
Consult any other range of pressure with the supplier
c)
Weight is indicative and only applies to the product without accessories
Applies to ambient temperatures of <30°C PDP – pressure dew point
d)
Dependence of compressor output on working pressure
05/2022
V, Hz
l/min
bar
A
kW
l
m
bar
dB
%
°C
d)
bar
bar
°C
s
mm
kg
27
DK50 2x2V/10/M
230, 50
3x400, 50
185
8.0 – 10.0
15.4
9.0
2x1.2
110
-
12.0
≤-73.0
S1-100
 -40
< 3
˃11
˃ -40
235
1085x620x815
125
NP-DK50 2V 50, 2x2V 110-AD-A-2_05-2022
DK50 2x2V/110S/M
230, 50
3x400, 50
185
8.0 – 10.0
15.6
8.7
2x1.2
110
-
12.0
≤-57.0
S1-100
 -40
< 3
˃ 11
˃ -40
235
1200x755x990
196