Ambient temperature
and ventilation
Ambient temperature
The appliance is designed for a specific
climate class. Depending on the climate
class, the appliance can be operated at
the following temperatures.
The climate class can be found on
the rating plate. Fig. -
Climate class
SN
N
ST
T
Note
The appliance is fully functional within
the room temperature limits
of the indicated climatic class. If
an appliance of climatic class SN
is operated at colder room temperatures,
the appliance will not be damaged up to
a temperature of +5 °C.
Ventilation
Fig. !/6
The refrigeration unit is ventilated only via
the ventilation grille in the base. Never
cover the ventilation grille or place
anything in front of it. Otherwise
the refrigeration unit must work harder,
increasing the power consumption.
Permitted ambient
temperature
+10 °C to 32 °C
+16 °C to 32 °C
+16 °C to 38 °C
+16 °C to 43 °C
Installation location
Install the appliance in a dry, well
ventilated room. The installation location
should neither be exposed to direct
sunlight nor near a heat source, e. g.
a cooker, radiator, etc. If installation next
to a heat source is unavoidable, use
a suitable insulating plate or observe
the following minimum distances to a
heat source:
3 cm to electric or gas cookers.
30 cm to an oil or coal-fired cooker.
Undercounter
An attachment under certain worktops,
e.g. stone, glass or stainless steel, is
frequently not possible. You can order
accessories from customer service for
installation on the side walls.