• Unauthorized modifications or technical chan-
ges are prohibited.
• The warranty is only applicable, if the system
is installed correctly and in accordance to state
and local regulations.
• A valve (shut-off valve) must be installed on
the inlet of the filter system (not included in the
scope of delivery)
• For the connection of the filter system appropri-
ate hoses according DVGW W 543 or NSF 61
have to be used.
• If the product was stored below freezing point,
the filter should be stored unwrapped for
24  hours under installation conditions before
installation.
• Do not install the filter system close to a heat
source or open fireplace.
• The filter system should not come in contact with
chemicals, dissolvers and vaporous dissolvers.
• The place of installation must be protected
against freezing and any direct or indirect sun
light.
NOTE!
• The non return valve is approved according DIN
EN 13959 and integrated in the filter head.
• Devices with boilers or water tanks such as
coffee machines have to be cleaned, rinsed and
sanitized before operating the filter system to
ensure the protection.
• For immunocompromised people and for babies
it is recommended to boil the water before use.
This should be done for filtered and unfiltered
water.
• For the protection against microbiological
growth the filter contains a small amount of
silver („bacteriostatic"). Therefore, there might
be a harmless release of silver in concentra-
tions below the recommendations of the World
Health Organisation (WHO).
4.2 Qualified staff
Only authorized, instructed and specially trained
personnel (professional plumber) are allowed to in-
stall, start up and maintain the filter system.
• Authorized Personnel are to have the Instruc-
tions about the assigned tasks and possible risks
in case of misuse.
• Professionals who are able to install, start up
and maintain the filter system, because of their
training, experience and knowledge of appli-
cable guidelines and codes.
14
EBA_Woda-Pure_Clear_finalB.indd 14
4.3 Operation after a shut down
• The inlet valve (shut-off valve) has to be closed
in case of a shut down.
• If the shut down was more than two days (week-
end, holiday....) the filter system has to be
rinsed with 4 - 5 liters before use.
• After a shut down period of more than 4 weeks
the filter cartridge has to be replaced.
4.4 Replacement interval
The filter cartridge has to be replaced if:
• the capacity (see Chapter 2.2 and Table at the
end of this manual) is reached.
• We recommend to replace the filter after 6
months after installation regardless of the remai-
ning capacity.
• there was a shut down longer than 4 weeks.
4.5 Disposal
Used filter cartridges, all other parts and the wrap-
ping foil must be disposed according the local rules.
To protect the environment, recycling is recommen-
ded and appreciated.
5. Function of the filter system
5.1 Assigned use of Woda-Pure Clear, S, V, M, XL
Woda-Pure Clear filter cartridges are used to decar-
bonize cold water fulfilling the legal requirements of
drinking water. They reduce the scale content and
total hasrdness of drinking water. The taste of food
and the aroma of drinks are imporved by adding
magnesium.
5.2 Construction/Function of Woda-Pure Clear S,
V, M, XL
The tap water is entering the filter system and an ion
exchanger decarbonizes the water. Simultaneously
the water is enrichted with magnesium. Natural pig-
ments as well as unpleasant odours and tastes are
removed by activated carbon.
6. Installing the filter system
6.1 Water quality
The filter system must be operated with cold water
fulfilling the legal requirements for drinking water.
i
WARNING
In any case of usage against the intended use e.g.
poor water quality, not reaching the criteria for drin-
king water there is a risk of health.
6.2 Pressure
A minimum inlet flow pressure of 1.2 bar is required
for the function of the filter system. In the event of
pressure fluctuations and pressure shocks, the sum of