Herunterladen Inhalt Inhalt Diese Seite drucken

Nominal Data; Technical Description; Motor Protection; Conformity With Standards - SystemAir 37407 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3.2 Nominal data

M4E068-DF
Motor
Phase
1~
Nominal voltage / VAC 230
Frequency / Hz
50
Method of obtaining
ml
data
Valid for approval/
CE
standard
1350
Speed (rpm) / min
-1
Power consumption / W110
Current draw / A
0.52
Capacitor / µF
3
Capacitor voltage / VDB400
P0 (CE)
Capacitor standard
Max. back pressure / Pa70
Min. ambient
-25
temperature / °C
Max. ambient
65
temperature / °C
Starting current / A
1.2
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
Subject to change

3.3 Technical description

5.7 kg
Weight
Fan size
315 mm
Rotor surface
Painted black
Terminal box material PC/ABS plastic
Blade material
PP plastic
Sheet steel, pre-galvanized and coated
Fan housing material
with black plastic
Guard grille material
Steel, coated with black plastic (RAL
9005)
Number of blades
5
Airflow direction
"A"
Clockwise, viewed toward rotor
Direction of rotation
Degree of protection
IP44; installation- and position-dependent
as per EN 60034-5
"F"
Insulation class
Moisture (F) /
H0+
Environmental (H)
protection class
Installation position
Shaft horizontal or rotor on bottom; rotor
on top on request
On rotor side
Condensation
drainage holes
Mode
S1
Ball bearing
Motor bearing
Touch current
< 0.75 mA
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
Electrical hookup
Via terminal box, capacitor integrated and
connected
Operating instructions

Motor protection

with cable
Protection class
1~
230
Motor capacitor
60
according to EN 60252-
1 in safety protection
ml
class
Conformity with
CE
standards
1490
148
0.66
3
400

3.4 Mounting data

P0 (CE)
85
; Secure the screws against unintentional loosening (e.g. use self-
-25
Strength class of
70
screws
Any further mounting data required can be taken from the product drawing.
1.18

3.5 Transport and storage conditions

; Use the device in accordance with its degree of protection.
Max. permitted
ambient temp. for
motor (transport/
storage)
Min. permitted
ambient temp. for
motor (transport/
storage)
Thermal overload protector (TOP) with
basic insulation
Axial
I (with customer connection of protective
earth)
P0/S0
EN 60335-1; CE
With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult Systemair for
support.
locking screws).
8.8
+ 80 °C
- 40 °C

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Aw 315e4 sileo

Inhaltsverzeichnis