Maintenance and care
6.2

Trouble shooting

ERROR
The clamping-power is not big
enough, the load is slipping out
(optional)
(optional)
(Adjustment of the opening width)
(optional)
(Property of material)
Unbalanced load
(Adjustment of the opening width)
(optional)
Automatic release does not work
mechanical (optional)
6.3

Repairs

Only persons with the appropriate knowledge and ability are allowed to repair the device.
Before the device is used again, it has to be checked by a qualified person or an expert.
57200020
CAUSE
The grippers are worn
The maximum load is exceed
The actual opening width is not
correct
The surface of the material is
dirty or the material is not suitable
/ allowed for this device.
The device is not loaded
symmetrically
The adjustment of the opening
width is not symmetrical.
Automatic release does not work
15 / 17
REPAIR
Replace the grippers
Reduce the weight of. the load
Adjust the opening width
according to the load you want to
transport
Check the surface of the material
or ask the manufacturer, if you
the material is allowed for this
device.
Adjust the position of the load
Correct the adjustment of the
opening width
Clean automatic release with
high pressure-cleaner
Oil the automatic release (never
with grease)
Correct faulty switching (→see
chapter "Picture of the automatic
release")
Change the inset of the automatic
release
GB