3.5 I Appliance's status

To check most of the appliances estatus, both inputs and outputs, the left
between the different screens of useful information.
3.5.1 Appliance's probes information
3.5.2 Appliance's dehumidifying information
3.5.3 Appliance's heating information
3.5.4 Appliance's titanium condenser information
• Humidity: Current relative humidity reading.
• Temperature: Current air temperature reading.
• Diff. Pressure: Measurement, in Pa, of the current differential
pressure that the fan is experiencing, used to calculate the real air
flow through the appliance.
• Evap. T.: Current reading of the evaporator coil temperature.
• Humidity: Current relative humidity reading.
• Set point: Current relative humidity setpoint.
• Compressor: Current status of the compressor: ON or OFF.
• Evap. T.: Current reading of the evaporator coil temperature.
• Defrost: Current status of the defrost process: ON or OFF.
• Temperature: Current air temperature reading.
• Air temp. set point (air heating kits): Current air temperature
setpoint.
• Enable: If air heating kit is enabled or not: ON or OFF.
• Heating.: If the air heating kit is activated or not: ON or OFF.
• Temperature: Current air temperature reading.
• Air set point (titanium condenser): Setpoint that defines from what
air temperature the titanium condensation will be activated.
• Pump: If the appliance is requesting water flow: ON or OFF.
• Solenoid: If the frigorific circuit is condensing in the titanium
exchanger: ON or OFF.
and right
keys are used to navigate
EN
29

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis