Herunterladen Inhalt Inhalt Diese Seite drucken

Accessories; General; Rc 100 Remote Control; Rc 120 Pedal Remote Control Unit For Tig Welding - voestalpine Bohler welding TERRA 270 TLH Betriebsanweisung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 35

4 ACCESSORIES

4.1 General

Operation of the remote control is activated when connected
to the power sources. This connection can be made also with
the system power on.
With the RC control connected, the power source control panel
stays enabled to perform any modification. The modifications
on the power source control panel are also shown on the RC
control and vice versa.

4.2 RC 100 remote control

The RC 100 is a remote control unit designed to manage the
display and the adjustment of the welding current and voltage.
"Consult the instruction manual".

4.2 RC 120 pedal remote control unit for TIG welding

The output current is controlled from a
minimum to a maximum value (can be
entered from SETUP) by varying the foot
pressure on the pedal surface. A micros-
witch provides the start trigger signal at
minimum pressure.
"Consult the instruction manual".

4.3 RC 180 remote control

This remote control unit makes it possible to change the output
current without interrupting the welding process.
"Consult the instruction manual".

4.4 RC 200 remote control

The RC 200 is a remote control unit designed to manage the
display and the adjustment of all available parameters of the
power source to which it is connected.
"Consult the instruction manual".

4.5 U/D series torches

The U/D series torches are digital TIG torches allowing the main
welding parameters to be controlled:
- welding current
- program recall
"Consult the instruction manual".

5 MAINTENANCE

Routine maintenance must be carried out on the
system according to the manufacturer's instruc-
tions.
Any maintenance operation must be performed by qualified
personnel only.
When the equipment is working, all the access and operating
doors and covers must be closed and locked.
Unauthorized changes to the system are strictly forbidden.
Prevent conductive dust from accumulating near the louvers
and over them.
Disconnect the power supply before every opera-
tion!
Carry out the following periodic checks on the
power source:
- Clean the power source inside by means of low-
pressure compressed air and soft bristle brushes.
- Check the electric connections and all the con-
nection cables.
For the maintenance or replacement of torch components,
electrode holders and/or earth cables:
Check the temperature of the component and
make sure that they are not overheated.
29

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis