Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 35

3.2.1 Set up

Permits set up and adjustment of a series of additional parameters
for improved and more accurate control of the welding system.
The parameters present at set up are organised in relation to the
welding process selected and have a numerical code.
Entry to set up: by pressing the encoder key for 5 sec.
Selection and adjustment of the required parameter: by
turning the encoder until displaying the numerical code relating
to that parameter. If the encoder key is pressed at this point,
the value set for the parameter selected can be displayed and
adjusted.
Exit from set up: to quit the "adjustment" section, press the
encoder again.
To exit the set up, go to parameter "O" (save and quit) and press
the encoder.
List of set up parameters (MMA)
0
Save and quit
Allows you to save the changes and exit the set up.
1
Reset
Allows you to reset all the parameters to the default
values.
3
Hot start
Allows adjustment of the hot start value in MMA.
Permits an adjustable hot start in the arc striking phases,
facilitating the start operations.
Parameter set as a percentage (%) of the welding current.
Minimum Off, Maximum 500%, Default 80%
7
Welding current
Permits adjustment of the welding current.
Parameter set in Amps (A).
Minimum 3A, Maximum Imax, Default 100A
8
Arc force
Allows adjustment of the Arc force value in MMA.
Permits an adjustable energetic dynamic response in
welding, facilitating the welder's operations.
Increasing the value of the arc force to reduce the risks
of sticking of the electrode.
Parameter set as a percentage (%) of the welding current.
Minimum Off, Maximum 500%, Default 30%
204
Dynamic power control (DPC)
It enables the desired V/I characteristic to be selected.
I = C Constant current
The increase or reduction in arc length has no effect on
the welding current required.
Basic, Rutile, Acid, Steel, Cast iron
1÷ 20* Falling characteristic with adjustable slope
The increase in arc length causes a reduction in welding
current (and vice versa) according to the value imposed
by 1 to 20 amps per volt.
Cellulose, Aluminium
P = C* Constant power
The increase in arc length causes a reduction in the
welding current (and vice versa) according to the law:
V.I = K.
Cellulose, Aluminium
26
205
MMA Synergy
Allows you to set the best arc dynamics, selecting the
type of electrode used:
0 Basic
1 Rutile
2 Cellulose
3 Steel
4 Aluminium
5 Cast iron
Default 0
Selecting the correct arc dynamics enables maximum
benefit to be derived from the power source to achieve
the best possible welding performances.
Perfect weldability of the electrode used is not guaran-
teed (weldability depends on the quality of the consum-
ables and their preservation, the operating and welding
conditions, the numerous possible applications, etc.).
312
Arc detachment voltage
Allows you to set the voltage value at which the electric
arc switch-off is forced.
It permits improved management of the various operat-
ing conditions that occur. In the spot welding phase,
for example, a low arc detachment voltage reduces
re-striking of the arc when moving the electrode away
from the piece, reducing spatter, burning and oxidisa-
tion of the piece.
If using electrodes that require high voltages, you are
advised to set a high threshold to prevent arc extinction
during welding.
Never set an arc detachment voltage higher than
the no-load voltage of the power source.
Parameter set in Volts (V).
Minimum 0V, Maximum 99.9V, Default 57V
500
Allows access to the higher set-up levels:
USER: user
SERV: service
vaBW: vaBW
551
Lock/unlock
Allows the locking of the panel controls and the inser-
tion of a protection code (consult the "Lock/unlock"
section).
601
(U/D) Adjustment step
Permits adjustment of the variation step on the up-
down keys.
Minimum Off, Maximum MAX, Default 1
602
CH1 External parameter
Allows the management of external parameter 1 (mini-
mum value).
603
CH1 External parameter
Allows the management of external parameter 1 (maxi-
mum value).
750
Measurements
Permits selection of the type of measurement to be
shown on the display 4.
A Real current
U Real voltage
751
Current reading
Allow the real value of the welding current to be dis-
played.
752
Voltage reading
Allows the real value of the welding voltage to be dis-
played.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis