Mounting and Connection Instructions Electromechanical Blocking Element 1
A borehole is required in the frame (6 mm) for mechanical emergency unlocking. If
necessary, this can be attached using the drilling jig or according to the dimensioned
drawing 3.1
The
threaded sleeve
is suitable for door leaves of wood and is turned into a borehole
according to the core diameter. If the
doors), ensure whether the flange requires sinking and how far. (For distance, see
dimensioned drawing 3.1).
ATTENTION:
The distance between the face plate and the counter unit (or the
threaded sleeve) should be kept as small as possible and should not
exceed 4 mm.

3.3 Installation aid for positioning the bolt counter unit

3.3.1 General
For determining exactly the position of the counter unit in the door leaf, we offer the
following aids:
- Installation aid, Item no. 019028
- Adhesive pad,
8 mm, adhesive on both sides
The round pads are enclosed with the blocking element.
3.3.2 Preparation
After successfully installing the blocking element in the door frame, proceed as follows:
Connect the blocking element as shown in the following illustration.
A battery or power supply (12 V DC) can be used to supply the voltage. Pay attention
to the correct polarity when connecting.
Note:
When the operating voltage is applied, the locking bolt always moves into the
"OPEN" position.
Operating voltage
0V
(e.g. from accumulator)
+12V DC
blue
red
Blocking element
yellow
black
The locking bolt can now be moved to the "OPEN" (access authorized) or "CLOSED"
position by pushing the slide switch.
counter unit with flange
is used (e.g. metal
(for controlling the bolt )
-
}
9-15 Volt
+
bl
rt
ge
sw
AUF
Open
ZU
Closed
20
Mounting and Connection Instructions Electromechanical Blocking Element 1
19
3.3.3 Installing the counter unit or the threaded sleeve
-
Move the bolt to the "OPEN" position.
-
Remove the adhesive pad from the foil and glue it exactly in the center of the bolt.
-
Remove the protective foil from the adhesive pad.
-
Close the door (the lock bolt must be latched into position).
-
Push the switch on the installation aid into the "CLOSED" position.
The bolt now tries to extend, the end position however, is not reached. The "slip
clutch" integrated in the blocking element prevents damage (rattling noise). After
approx. 1 second, actuation is automatically interrupted.
-
Push the switch on the installation aid into the "OPEN" position and the bolt is
retracted again.
-
Open the door.
-
The adhesive pad now sticks to the door leaf and indicates the exact position of the
counter unit.
-
Mark the center with a center punch and drill the borehole. (The borehole diameter
must match the counter unit. )
-
After drilling the borehole, the counter unit can be installed.
-
Perform the function test using the installation aid.