Mounting and Connection Instructions
Electromechanical Blocking Element 1
Item no. 019030.20
(without magnetic contact)
Item no. 019033
(with magnetic contact)
Contents
1.
2.
3.
4.
5.
6.
7.
8.
9.
P00720-10-002-04
G195097 (Class C for BE)
G103521 (Class B for MC)
21.02.2007
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Mounting instructions . . . . . . . . . . . . . . . . . . . . . 17
3.1
Dimensioned drawing . . . . . . . . . . . . . . . . 17
3.2
Installation guidelines . . . . . . . . . . . . . . . . 18
3.3
the bolt counter unit . . . . . . . . . . . . . . . . . . 19
3.4
Magnetic contact (019033 only) . . . . . . . . . 21
Actuation possibilities . . . . . . . . . . . . . . . . . . . . . 22
Connection diagram . . . . . . . . . . . . . . . . . . . . . . 23
Emergency unlocking . . . . . . . . . . . . . . . . . . . . . 25
7.1
Electrical emergency unlocking . . . . . . . . . 25
7.2
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Accessories and spare parts . . . . . . . . . . . . . . . 27
Subject to change
without notice
16
Mounting and Connection Instructions Electromechanical Blocking Element 1
1. General
The motor-powered blocking element prevents access to the armed zone of an intrusion
detection system. (IDS).
The use of a blocking element has the following advantages:
m
An IDA can be armed by different arming elements at different positions.
m
Access to the secured zone can be prevented or authorized at one or several
locations.
m
It is easily mounted in the door frame. Only a borehole is required in the door leaf or
the counter unit for the locking bolt.
m
Integrated magnetic contact for monitoring of opening (019033 only).
m
Actuation is either dynamic or static.
m
Both electrical and mechanical emergency unlocking is possible.
2. Function
When the operating voltage is applied, the locking bolt is always retracted which is
equivalent to the position "Access authorized" (OPEN).
An operating voltage interruptor switch could enable this simple electrical emergency
unlocking.
The locking bolt is extended with the static or dynamic control signal "CLOSED" and
switched off in the end position. The bolt is also retracted with the corresponding control
signals.
If unauthorized, high counterpressure is applied to the bolt or the bolt jams,
- it is mechanically uncoupled and
- electrical actuation is interrupted after approx. 0.6 seconds.
The time the bolt requires to move depends on the operating voltage and ranges from
200 ms to 300 ms at an operating voltage range of 9.0 V to 15.0 V DC.
If the locking bolt does not move into the "OPEN" position electrically, emergency
unlocking can be activated using a tool (e.g. Screwdriver).
The blocking element 1 Item no. 019033 is also equipped with an additional magnetic
contact (reed contact). This permits open/close monitoring without additional opening
contact.