Connection between devices

On the rear panel, there is an IEC socket (Power Out). Connect the output with the input of the next fixture
until all fixtures are connected.

Connection with the mains

Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
Please note: A maximum of 8 EUROLITE LED Theatre 36x3W CW/WW theatre spot may be linked
together. After every 8 devices, the fixtures must have a renewed connection with the power mains.

OPERATION

After you connected the spot to the mains, the EUROLITE LED Theatre 36x3W CW/WW theatre spot starts
running.
The LCD display lights up and you can choose the desired mode via the MODE button:

DMX MODE

-
-
Dimming MODE
-
PRESET MODE
-
MASTER/SLAVE MODE
DMX MODE
The Control Board allows you to assign the DMX fixture address, which is defined as the first channel from
which the LED Theatre 36x3W CW/WW theatre spot will respond to the controller.
If you set, for example, the address to channel 6, the LED Theatre 36x3W CW/WW theatre spot will use the
channel 6 to 10 for control.
Please, be sure that you don't have any overlapping channels in order to control each LED Theatre 36x3W
CW/WW theatre spot correctly and independently from any other fixture on the DMX-chain.
If several LED Theatre 36x3W CW/WW theatre spot are addressed similarly, they will work synchronically.
Controlling:
After having addressed the LED Theatre 36x3W CW/WW theatre spot, you may now start operating it via
your lighting controller.
Note: It's necessary to insert the XLR termination plug (with 120 Ohm) in the last lighting in the link in order
to ensure proper transmission on the DMX data link.