Connection between devices
On the rear panel, there is an IEC socket (Power Out). Connect the output with the input of the next fixture
until all fixtures are connected.
Attention: It is recommended to renew the connection with the power mains after every 8 devices.
Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
After you connected the spot to the mains, the EUROLITE LED SCY-200 TCL DMX starts running and the
display lights up.
The device has two operating modes. It can be operated in Stand-Alone or in DMX-controlled mode.
You can choose the desired mode via the buttons MENU, UP and DOWN:
Internal Programs – Auto Mode
Press the MODE button until the display shows P- to set the internal programs.
You can choose the desired program (P – 1 to P – 10) via the UP and DOWN buttons:
Press the MODE button again until the display shows an S-. Via the UP or DOWN buttons you can set the
desired speed of the program (S1 bis S100).
Sound control
Press the MODE button until the display shows SoUd to set the Sound Control Mode.
Setting the Sound Sensitivity
You can do without a controller as the device features a built-in microphone, which provides automatic sound
control. You can adjust the sensitivity with the rotary-control on the rearpanel.
International
L
N
21/26