Filter tank BÜHNE² / Maintenance

7.3 Clean the pump's primary screen

The primary screen must be regularly checked for contamination.
Contamination significantly reduces the pump performance.
Switch off filter system.
Close the shut-off valves in the pressure and suction pipe.
Select valve function "Closed".
Open the primary screen lid and remove the primary screen.
Remove coarse dirt from the screen.
Clean the screen under running water with a brush.
Reinsert the screen and close the lid. Make sure the lid sits correctly.
Select valve function "Filter".
Open the shut-off valves in the pressure and suction pipe.
Switch on the system.
Completely vent the filter tank at the vent valve.

7.4 Storing the filter tank over winter

To protect the filter tank and water-bearing components from frost, they must be emptied of water during
periods of frost.
To do this, remove the drain plug (16).
Please note, a little water may drip out of the drain.
Attach the supplied Gardena hose coupling. Seal it properly with Teflon tape.
Place the hose into a sufficiently-sized floor drain and open the aeration and ventilation
valve.
Reinstall the drain plug (16) properly.
22
NOTE
The pump may be damaged!
Do not switch on the pump during cleaning!
CAUTION
Procedures on technical systems by non-experts may lead to injuries and
material damage.
NOTE
Over 1,000 litres of water can flow out of the tank here.